The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using it for any purpose other than the
use of the products or the execution of the project to which it refers, and from communicating it to third parties without Automatic Systems’ prior written agreement.
Document subject to change without notice.
First
Lane
-MT-EN
p.
40 / 48
M
OTHERBOARD
(CPU)
AS
1190
CN1: 24 VDC.
CN2: USB device
CN3: RS232 link
CN4: CAN 0 Bus
CN5: CAN 0 Bus
CN6: CAN 1 Bus
CN7: COM serial debug link
CN9: CAN 1 Bus
CN10: RS485 link
CN11: I/O extension BUS
CN12: I2S interface with AS 1106 card
(speech synthesis card)
CN13: Ethernet100 Mbps RJ45 link
CN14: Ethernet100 Mbps RJ45 link
CN16: USB 2.0 host
LD1: Voltage present indicator light
(Green)
LD2: EMMC memory access (Yellow)
LD3: User LED (Green)
LD4: CPU activity (heartbeat) indicator
light (Red)
LD5: CAN 0 bus node status indicator light
(Yellow)
LD6: CAN 1 bus node status indicator light
(Yellow)
LD7: Incorrect battery position indicator
light (Red)
S1:
CPU Reset
S2:
Program Restart
S3:
Shutdown
S4:
Recovery of factory IP address
(
192.168.0.200
) if pressed at start-up or for
20 sec.
If LED LD7, which indicates the incorrect position of the battery, is lit
(red), invert the position of the battery in its holder.
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN
INCORRECT TYPE.
DISPOSE OF USED BATTERIES IN ACCORDANCE WITH
THE INSTRUCTIONS (
S4
S1
S3
S2
LD2
LD3
LD4
LD6
LD1
CN16
CN2
CN13
CN14
CN11
CN12
CN3
CN10
CN1
CN9
CN4
CN5
CN6
CN7
LD5
ETH1
ETH2