First
Lane
-MT-EN
p.
26 / 48
S
OUND AND
L
IGHT
A
LARMS
Function pictogram
The function pictogram is integrated into the upper section of the extension cover and operates
independently in the 2 directions of passage.
•
Off
Lane powered off
•
Blue
Lane initializing
•
White
Lane in Controlled mode, waiting for a request for
passage authorization
•
Flashing green
Access to lane authorized in the direction shown
Lane in Evacuation mode
•
Green
User must pass the obstacles before losing the
passage authorization
Lane in Free mode
•
Red
Passage Prohibited
Passage under way in the wrong direction
Lane out of service
•
Flashing red
Violation detected
•
Yellow
Maintenance mode
Sound alarm (buzzer)
The buzzer is activated when an anomaly is detected during the passage sequence:
•
Continuous sound
Intrusion or prolonged presence in the security zone during open/close
•
Intermittent sound
Fraud
Blue
White
Red
Green
Yellow