2
In the Insert Component: JIC Schematic Symbols dialog box, click Relays/
Contacts.
3
In the JIC: Relays and Contacts dialog box, click Relay NO Contact.
4
Respond to the prompts as follows:
Specify insertion point:
Position the cursor on the wire at line reference 404 near the hot wire and click
(1)
The Insert/Edit Child Component dialog box displays. Notice that
AutoCAD Electrical did not automatically assign a tag name for the relay
contact; there is just a generic “CR” in the edit box. Determine the relay
contact tag name. A relay contact is a child component that must link
to a parent relay coil on a drawing in the active project. The child gets
the same tag name that is found on the parent relay coil.
Assign the tag name by clicking Parent/Sibling and picking the parent in
the drawing. Or, click Drawing or Project to select from a list of
components with the same family name.
5
In the Insert/Edit Child Component dialog box, Component Tag section,
click Drawing.
6
In the Active Drawing list for FAMILY=”CR” dialog box, select:
MCAB5 CR403 MASTER CONTROL RELAY
30 | Chapter 4 Schematic Components