Gas operation (heating and hot water)
a Rotary switch for room temperature (1 – 5)
b green LED lit ‘Operation’ green LED
blinking ‘after-running’ is active in order to
reduce the unit’s temperature
c Summer operation
(water temperature 40° C or 60° C)
d Winter operation (heating without water
temperature monitoring or with drained
water system)
e Winter operation (heating with water
temperature monitoring)
f Rotary ‘Off’ switch
g Yellow LED lit ‘Boiler heat-up phase’
h Red LED lit, red LED blinking ‘Failure’
The LEDs are visible only when the unit is
switched on.
Room thermostat
i Room temperature sensor
To measure the room temperature, an external
room temperature sensor (i) is located in the
vehicle. The location of the sensor is
determined individually by the vehicle
manufacturer, depending on the vehicle type;
consult the operating instructions for your
vehicle for further details.
The thermostat setting on the control panel
(1 – 5) must be determined individually
depending on the heating requirement and
the type of vehicle. For an average room
temperature of about 23° C, we recommend a
thermostat setting of about 4.
Taking into operation
Heating operation is basically possible without
restriction with or without water content.
Check to make sure the cowl is unobstructed.
Be sure to remove any covers that may
be present.
Turn on gas cylinder and open quick-acting
valve in the gas supply line.
Summer operation (boiler operation only)
Move the rotary switch on the control panel to
position (c – summer operation) 40° C or 60°
C. The green (b) and yellow (g) LEDs light up.
After reaching the set water temperature
(40° C or 60° C), the burner will switch off and
the yellow LED (g) will be extinguished.
Winter operation
Heating with water temperature monitoring
Set the rotary switch to the operational
setting ‘e’. Set the rotary switch (a) to the
desired thermostat setting (1 – 5). The green
LED (b) for operation is lit and simultaneously
indicates the position of the selected room
temperature. The yellow LED (g) indicates the
water’s heat-up phase.
The unit automatically selects the required power
level according to the temperature difference
between the setting on the control panel and
the current room temperature. Once the room
temperature set on the control panel has been
reached, the burner switches back to the lowest
stage, and heats the water content to 60° C.
The yellow LED (g) will be extinguished after the
water temperature is reached.
Heating without water
temperature monitoring
Set the rotary switch to the operational setting
‘d’. Turn the rotary switch (a) to the desired
Содержание 2012 Van Conversion Range
Страница 1: ...2012 owners handbook van Conversion range ...
Страница 4: ...2 co nt e n ts ...
Страница 6: ...4 wa rr an t y inf or mat io n ...
Страница 15: ...th e mo t orh ome code 13 the motorhome code Code of Conduct 14 The Country Code 15 The Coastal Code 16 ...
Страница 25: ...e n r ou t e 23 en route Panel van spare wheel detail 24 Cruise Control 24 ...
Страница 34: ...sa f e t y se curity 32 safety security ...
Страница 35: ...a rriva l at s it e 33 arrival at site Positioning the Motorhome 34 ...
Страница 55: ...e le ct rica l syst e ms 53 electrical systems Motorhome battery 56 EC400 Power Control System 56 ...
Страница 132: ...e q u ip me nt de ta il s 130 ...
Страница 140: ...138 u se fu l inf or matio n ...
Страница 144: ...u se fu l inf or matio n 142 useful information ...
Страница 145: ...u se f u l inf or mat ion 143 useful information ...
Страница 148: ...u se fu l inf or matio n 146 ...
Страница 149: ...u se f u l inf or mat ion 147 ...
Страница 150: ...u se fu l inf or matio n 148 ...
Страница 152: ...u se fu l inf or matio n 150 ...