background image

 

 

5.2.2 Type 

Select the correct I/O Cabinet type from the range of supported I/O Cabinets. This menu 
option is available only if the panel is configured to be the Main Panel. 

 

 

 

Page 32 (49)  

 

Make sure the selected I/O Cabinet type is matching the actual I/O in the I/O 
Cabinet. Otherwise, unpredictable behavior can occur. 

Содержание Marine Watch I/O Cabinet

Страница 1: ...Publication P N 1050161 User Manual Marine Watch S Series S ONE Alarm Panel S ACE Annunciator Panel I O Cabinet...

Страница 2: ...uage 18 4 1 5 Buzzer 19 4 2 Display 19 4 2 1 Brightness 20 4 2 2 Mode 20 4 2 3 Theme 20 4 2 4 Clean Screen 20 4 2 5 Sparkline 21 4 2 6 Date Time 21 4 2 7 Screensaver 21 4 3 Event Log 22 4 4 Troublesho...

Страница 3: ...tch S Series Alarm Panel 1 3 1 Software revisions See this document for S ONE Alarm Panel software revisions See this document for S ACE Annunciator Panel software revisions 1 3 2 User Manual revision...

Страница 4: ...or and the buzzer sounds An operator can acknowledge the event by touching the rectangle Additional S ONE Alarm Panels can be added in the network and these are designated Subpanels Finally several S...

Страница 5: ...3 1 Main Panel One of the S ONE alarm panels shall in the configuration be designated the Main Panel This is the default setting The Main Panel shall be configured and holds the entire system configu...

Страница 6: ...dministrative menu select I O Cabinet Network Enter the replacement panel IP address 2 If several S ACE Annunciator Panels are in use then make sure all IP addresses are unique 3 If several I O Cabine...

Страница 7: ...6 NMEA 2000 isolated 7 Ethernet 1 RJ45 8 Ethernet 2 RJ45 for network communication 9 2x USB A 10 USB A 11 HDMI out 1 CAN bus 2 Relay 3 Modbus RTU 4 Flexible I O 5 Power supply 12 V 24 V Connectivity P...

Страница 8: ...Panel using the built in Modbus TCP interface on Ethernet The communication I O list can be found here http tiny cc zxxebz Page 8 49 Interface Power Indication Lit when the panel is powered NFC Sensor...

Страница 9: ...to control different parts of the panel as described below 2 7 Output Signals Marine Watch includes a standard set of output signals in the I O Cabinet See the chapter for the I O Cabinet for further...

Страница 10: ...nts It is solid lit for acknowledged events Various status symbols The Time can be displayed as an option 3 1 1 Header Status Symbols These symbols may appear in the header bar 4 The red alarm banner...

Страница 11: ...Cabinet Each rectangle represents the status of one switch input channel and each page can display status from up to 60 channels Channels can optionally be assigned to one of three different groups an...

Страница 12: ...ctive and acknowledged The channel is acknowledged by an operator and will clear when the alarm clears Regular text Inactive and not acknowledged The channel has activated but is not active now It wil...

Страница 13: ...of 16 analog channels Page 13 49 Analog channels are an option If the I O Cabinet does not include the analog option then these pages are not displayed Widget Properties Name The analog signal descrip...

Страница 14: ...owledged The channel is alarming following its persistence timer Instrument text in bold flashing Active and acknowledged The channel is acknowledged by an operator and will clear when the alarm clear...

Страница 15: ...Page 15 49 Disabled The channel has been disabled by an operator Disabled but active event The channel has been disabled by an operator and is indicating an event...

Страница 16: ...ly the Main Panel can control the outputs 3 5 Screen Navigation This is how to operate and navigate the panel Page 16 49 Action Do this Acknowledge an event Tap the event widget The event widget is th...

Страница 17: ...ngs are used most frequently 4 1 1 Display Page 17 49 Brightness Brightness slider Manually adjust the backlight brightness Auto The backlight brightness is adjusted automatically Note Using the physi...

Страница 18: ...ge is divided into three rows switch channels analog channels and output channels 4 1 3 Grouped Channels If a channel is assigned to a group it can be indicated with a colored rectangle and an optiona...

Страница 19: ...Display Page 19 49 Panel Buzzer Off Silenced Low 50 volume Normal 100 volume Panel Buzzer Pattern Standard Standard on off pattern Annoying Four quick beeps Touch Feedback Off Silenced Low 50 volume N...

Страница 20: ...set Auto to Off Mode Day Colors optimized for daylight Night Colors optimized for use in dark environments Auto Switch automatically between Day and Night modes Theme Day Mode Choose a color represen...

Страница 21: ...e Date and time formatting can be selected together with the option of displaying the time in the header 4 2 7 Screensaver Page 21 49 Screensaver Screensaver Enables the screensaver The screensaver wi...

Страница 22: ...torage device It is possible to filter the Event Log further by pressing and holding the event Type or the event symbol eg the warning triangle Page 22 49 If the Event Log is filtered a Show All butto...

Страница 23: ...d here Unacknowledged events are listed in bold Press the corresponding Acknowledge button to acknowledge the event The following internal events are defined Page 23 49 Indication Supply Voltage The p...

Страница 24: ...ply Circuit Breaker Tripped I O Cabinet circuit breaker tripped Status Switch 1 605 See the status of the binary channel at the I O Cabinet Analog 1 86 See the status of the analog channel at the I O...

Страница 25: ...configured panel type The latter can be either Main Panel or Subpanel 4 5 2 I O Cabinet This section lists the I O Cabinets in use Each I O Cabinet lists the IP address and the I O Cabinet capacity 4...

Страница 26: ...ear Page 26 49 Three failed PIN code attempts will result in a PIN code lockout for 5 minutes and also an encrypted PIN code Buttons Press the Log In button to access the login dialogue Already logged...

Страница 27: ...Panel This section holds the top level configuration of this panel 5 1 1 Panel Type Choose between Main Panel and Subpanel If this is the only Alarm Panel in the network then it shall be a Main Panel...

Страница 28: ...vice is inserted first A saved configuration file will be named config ini and overwrite any current file on the USB storage device 5 1 4 Maintenance Change PIN Code Dialogue for changing the active P...

Страница 29: ...device with a software update file marine watch image mender and press the Software Update button to start the update 5 1 5 Network Set the IP address of this Alarm Panel The default IP address is 19...

Страница 30: ...of the Acknowledge Button Configures the behavior of a long press on the acknowledge button System wide Buzzer Silence Configures the behavior of the buzzer in the entire system Page 30 49 Acknowledge...

Страница 31: ...stem currently supports connection with up to four I O Cabinets In each I O Cabinet locate the bus coupler and set the rotary switches S1 and S2 as follows Page 31 49 I O Cabinet S1 S2 IP address I O...

Страница 32: ...range of supported I O Cabinets This menu option is available only if the panel is configured to be the Main Panel Page 32 49 Make sure the selected I O Cabinet type is matching the actual I O in the...

Страница 33: ...word wrapping is performed automatically Type Choose Warning or Alarm depending on the required event type Switch Type A Normally Open NO channel activates when the switch is closed A Normally Closed...

Страница 34: ...n The text displayed in the circular gauge or bar graph Maximum 45 characters and four lines of text word wrapping is performed automatically Value Band The Value Band toggles the visibility of the ga...

Страница 35: ...at After the elapsed repeat time in seconds the channel will re enable the buzzer unless the channel is acknowledged The repeat timer starts when the buzzer is silenced Make sure the connected analog...

Страница 36: ...ype Press the channel number to enable or disable that channel Description The text displayed in the circular gauge or bar graph Maximum 45 characters and four lines of text word wrapping is performed...

Страница 37: ...els are by default not assigned to any group but can be assigned to any of the three available groups All panels in a network can acknowledge unassigned channels Channels that are assigned to a group...

Страница 38: ...evices NFC provides a wireless connection between a Marine Watch S Series Alarm Panel and an NFC device The latter is typically a mobile phone Page 38 49 This feature is not supported in this software...

Страница 39: ...ine Watch A common warning alarm banner The entire center of the header is flashing for new unacknowledged events It is solid lit for acknowledged events Event status symbols Page 39 49 The S ACE can...

Страница 40: ...p right of the warning alarm rectangles If the Annunciator Panel is not operated for one minute the Annunciator Panel will automatically default to show the Alarm View 7 The red alarm banner takes pre...

Страница 41: ...is locked by a selectable PIN code Page 41 49 Status Description Sample Graphic Representation Active and not acknowledged The channel is alarming following its persistence timer Text in bold flashin...

Страница 42: ...uently Display Page 42 49 Brightness Low Medium High Select the screen brightness Mode Day Colors optimized for daylight Night Colors optimized for use in dark environments Clean Screen Clean Screen D...

Страница 43: ...ata as follows This button is the entrance to the Administration Menu To log in press the Log In button then add the following info into the dialogue PIN code 1234 factory default If the PIN Code is l...

Страница 44: ...e network are unique Alarm Groups Select which groups of events this S ACE Annunciator Panel shall monitor Channels that are not assigned to any group will not be displayed if the Ungrouped switch is...

Страница 45: ...Main Panel Page 45 49 Network Set the IP address of the S ONE Main Panel...

Страница 46: ...t will remove and reset the following Configuration User PIN code Software Update Updates the software of the Annunciator Panel Insert a USB storage device with a software update file marinewatch_sace...

Страница 47: ...vailable ports on the Ethernet Switch and an alarm panel Multiple alarm panels can be connected 7 3 Switch Channels All switch input channels shall be connected directly to the I O module From the wir...

Страница 48: ...nal Output Channels All switch output channels shall be connected directly to the I O module From the wiring diagram locate the correct I O module and connect as follows Page 48 49 Analog channel 0 10...

Страница 49: ...channels The optional two output I O modules can source a maximum of 2 A in total 7 6 Alarm Panel Supply The I O Cabinet has circuit breaker 4Q35 reserved for 24 V 2 A power to one external alarm pane...

Отзывы: