![AUTEC C26PRO SERIES Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/autec/c26pro-series/c26pro-series_user-manual_3020248009.webp)
- 5 -
LIPROMA3-00
- 6 Warnings regarding rou
tine maintenance -
After each maintenance procedure, always make sure that only the
expected manoeuvres are carried out when the relative commands
are sent by the transmitting unit.
Summary
The prescriptions that follow should be considered as the minimum necessary for safe
and correct radio remote control operation. Special applications may need more spe-
cific routine maintenance procedures to be carried out at different periods.
These recommendations may never be considered as forming a contract, nor replace
any local, state or federal regulations concerning workplace safety. Furthermore,
these recommendations do not limit the responsibilities of the purchaser and/or user
of the radio remote control regarding safe work practices.
All the mentioned prescriptions must be carried out each time the machine
and the radio remote control are put into service.
If irregularities are noted while carrying out routine maintenance,
put the “radio remote control” system out of order, fol-
lowing the indications given (see chapter 7).
Transmitting
unit
The following must be completed daily:
1. remove dust or accumulations of other material from the transmitting unit. Never
use solvents or flammable/corrosive materials to clean, and do not use high pres-
sure water cleaners or steam cleaners.
2. store the transmitting unit in clean and dry areas.
3. make sure the transmitting unit's gaskets, joystick bellows, selectors caps and
pushbuttons are intact, soft and elastic
4. make sure that the battery seat and the battery contacts are always clean
5. make sure that the transmitting unit is structurally sound
6. make sure that the panel symbols can be easily recognized. If necessary, replace
the panel.
7. check identification plate readability and integrity
Receiving
unit
The following must be done every 3 months:
1. remove dust or accumulations of other material from the receiving unit. Never
use solvents or flammable/corrosive materials to clean, and do not use high pres-
sure water cleaners or steam cleaners.
2. make sure that the receiving unit is structurally sound
3. verify the integrity and connection of the internal wiring to the receiving unit
4. make sure that the panel symbols can be easily seen. If necessary, replace the
panel.
5. check identification plate readability and integrity
Electrical
operation
The following must be done every 6 months:
1. make sure that all the relay contacts of the receiving unit operate correctly, con-
trolling contact closing when the corresponding manoeuvre is enabled and con-
tact opening when the manoeuvre is disabled.
2. verify the correct correspondence between the commands that are sent and the
manoeuvres that are carried out.
External
electric
conductors
The following must be done every 12 months:
1. verify integrity along the full length of the cable which connects the receiving unit
to the machine.
2. verify the integrity and the electrical connection of the plugs and the connection
socket
PERIODIC CONTROLS
Component
Interval
Daily
Every 3
months
Every 6
months
Every 12
months
Transmitting unit
X
Receiving unit
X
Electrical operation
X
External electrical conductors
X