- 1 -

LIPROMA3-00

- 1 Conventions -

 1

CONVENTIONS

Any pieces of text written in 

bold 

should be read very carefully.

This symbol highlights extremely important indications and information
which, if not observed, can create seriously dangerous situations for people,
equipment or property.

This symbol highlights all important indications and information that deal
with operation.

 2

CONFORMITY

The C26 PRO series PRO-M radio remote control is in conformity with FCC
Rules (Part 90 for the transmitting unit and Part 15 for the receiving unit).

Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.

Changes or modifications not expressly approved by the party re-
sponsible for compliance could void the user’s authority to operate
the equipment.

In Technical Data (see chapter 15) there are the characteristics of safety functions
according with EN 954-1.

All machines must undergo a risk analysis; therefore it is necessary to evaluate, with-
in the limits of this analysis, if the machine can be radio remote controlled.
The machine producer and/or the person who decides upon radio remote control use
and installation is responsible for this analysis.

Autec, or its distributors, cannot be held responsible if the risk analysis is not
carried out correctly and if the radio remote control is installed on applica-
tions that are different from those permitted:

PERMITTED APPLICATIONS:
Hoisting and moving machines installed exclusively on vehicles that
use a battery as electrical power supply source (for example: hy-
draulic cranes, concrete pumps…)

FORBIDDEN APPLICATIONS
- machines installed in areas where equipment with explosion-

proof characteristics are being used

- AC supplied machines
- machines using a DC supply that does not come from a battery
- machines where risk analysis regarding verification of radio re-

mote control conformity to the application is not possible or has
given a negative or uncertain result.

To guarantee correct radio remote control operation, all current regulations regarding
safety at work and accident prevention should be respected. All applicable standards
and regulations valid in the user country regarding the use of both the machine and
the radio remote control MUST ALWAYS be respected.

Autec cannot be held responsible if the radio remote control is used in un-
lawful working conditions.

System must be installed by a licensed technician and in accordance with all
relevant local, state/provincial and federal regulations, including but not
limited to NEC, OSHA, CE etc.

Содержание C26PRO SERIES

Страница 1: ...PRO M C26PRO SERIES ...

Страница 2: ......

Страница 3: ...PRO M C26PRO SERIES ...

Страница 4: ...f the manual Specifying the KTC serial number Contact AUTEC if any of the instructions and or warnings given in this manual are not clear The information contained in this manual is subject to modification without notice and is not binding No parts of this manual may be produced by any means without the written permission of AUTEC including recording and photocopying ...

Страница 5: ...radio remote control use and installation is responsible for this analysis Autec or its distributors cannot be held responsible if the risk analysis is not carried out correctly and if the radio remote control is installed on applica tions that are different from those permitted PERMITTED APPLICATIONS Hoisting and moving machines installed exclusively on vehicles that use a battery as electrical p...

Страница 6: ... The safety circuits on the radio remote control and or present on the machine should not be bypassed or excluded The receiving unit wiring can be configured very easily therefore it can be installed without having to modify the machine Do not modify the machine electric panel with out the machine manufacturer authorization Disconnect the receiving unit by detaching all the electrical connec tions...

Страница 7: ...ady set depending on the valve type s During installation these values must be verified and if necessary modified according to machine function and operator preference see chapter 12 Testing When installation and wiring have been completed always do the following make sure that when the radio remote control STOP pushbutton is pressed the machine goes into a situation of safety through direct actio...

Страница 8: ...tor should never switch on or activate the transmitting unit unless ready to start working A radio link can be created even outside the active range and from enclosed places creating the pos sibility for the radio remote controlled machine to carry out undes ired commands In case of danger If a dangerous situation arises the operator must intervene imme diately by pressing the STOP pushbutton whic...

Страница 9: ...e intact soft and elastic 4 make sure that the battery seat and the battery contacts are always clean 5 make sure that the transmitting unit is structurally sound 6 make sure that the panel symbols can be easily recognized If necessary replace the panel 7 check identification plate readability and integrity Receiving unit The following must be done every 3 months 1 remove dust or accumulations of ...

Страница 10: ...heet Make sure that these documents are present If they are not please request them from Autec or an authorized representative specify ing the radio remote control serial number Instruction and warnings manual This manual is an integral part of the radio remote control and its safety functions and gives the main information necessary for installing using and carrying out mainte nance on the radio ...

Страница 11: ...sible to control the radio remote machine only after the transmitting unit has been radio linked to the receiving unit signalled by the lighting up of the ENABLE pilot light on the receiving unit see chapter 10 After the radio link is established machine movements are available by acting on the proper actuators All commands protected by the SAFETY function are approved to category 3 of EN 954 1 ag...

Страница 12: ...attery is fully discharged the red light will start flashing and an acoustic alarm will sound In this situation the operator must return the machine to a condition of safety by pressing the stop pushbutton switch off the transmitting unit and recharge the bat tery or fit a fully charged battery Power off Turn the ignition key to O Always remember to remove the starting keyswitch and put it in a sa...

Страница 13: ... on this indicates that the relative command relay given in the following drawing also present inside the receiving lid cover has been activated SAFETY The radio remote control is equipped with a safety function called SAFETY which pro tects the system from involuntary movements caused by possible radio remote con trol faults This function constantly controls the rest position neutral of the movem...

Страница 14: ...ure T S T S TIMED STOP is the command that switches off the machine diesel motor it re mains active for 10 seconds after the STOP pushbutton has been pressed Fuse The three fuses inside the receiving unit have the following characteristics Fuse Function Technical Data F1 POWER SUPPLY circuit protection 4A 32Vdc autofuse F2 STOP circuit protection 10A 32Vdc autofuse F3 SAFETY circuit protection 10A...

Страница 15: ...s and integrity of the RI97 08PVZA module the yellow LED indicates the status of the REMOTE SET UP function C1 connector for the proportional voltage outputs C2 connector for the proportional current outputs PWM C3 connector for the on off inputs C4 connector for the power supply C5 connector for the connection to the bus board D dip switches K1 data memory L LEDs P initial calibration restore pus...

Страница 16: ...REMOTE SET UP position Calibration 7 Select one or more positions of the rotary switch S on the RI97 08PVZA module to calibrate the related parameters 8 Operate the RPM selector on the transmitting unit where the increases the speed that is being calibrated and decreases it Moving the joystick outside of the standstill position during the cal ibration a horn alarm sounds for 0 5 seconds signalling...

Страница 17: ...use the related actuator on the transmitting unit and take it to its end limit Keep the same position and use the RPM toggle switch to set the desired value Once the maximum value has been set use the related actuator on the trans mitting unit and take it to the beginning to fix the minimum value Keep the same position and use the toggle switch RPM to set the desired value Position 5 inversion of ...

Страница 18: ... Is the red signalling LED on with a steady light Carry out receiving unit diagnostics Insert a battery that is charged Deactivate if active the actuator and or the STOP pushbutton If the transmitting unit does not switch on cor rectly CALL TECHNICAL ASSISTANCE Is the POWER light on Is the connection plug between the receiving unit and the machine connected correctly Correctly insert the connectio...

Страница 19: ...ower 433 MHz 10 mW Transmitting power 870 MHz 5 mW Power supply battery pack NiMH 7 2V 1 3 Ah Turn off voltage 6 0 V Battery capacity with fully charged battery at 20 C about 10 hours Flat battery warning about 3 min Working temperature 5 F 130 F 20 C 55 C Housing PA6 fg 20 Protection degree NEMA 4 IP65 Dimensions 9 3 x 6 3 x 6 8 263 x 160 x 173 mm Weight with battery 4 4 lbs 2 kg Receiving unit P...

Страница 20: ... 16 LIPROMA3 00 ...

Страница 21: ......

Страница 22: ...AUTEC s r l via Pomaroli 65 36030 Caldogno VI ITALY Tel 39 0444 901000 r a Fax 39 0444 901011 email info autec it http www autec it ...

Отзывы: