Dexter 

english 

 

Combustion air 

Being the user of the stove you must take care of  a sufficient combustion air supply. Sealed-up windows and doors may not allow a 

sufficient combustion air supply or  disturb the draught behaviour of your stove. Please ensure  the additional supply of fresh 

combustion air if necessary.  For details please consult your specialist retailer. Make sure that  the  combustion  air  intakes  are  not 

blocked! 

 

Stove pipe connection 

For your own safety stringent laws apply for connecting  stove pipes to the chimney. Your professional dealer or distributor 

knows these laws. Please have your certified retailer carry out the connection of your stove. 

 

Floor load capacity and Hearth 

Make sure that the load capacity of the  supporting construction is sufficient to carry the  weight  of  the  entire unit, before the 

heating unit is installed. 

 

The hearth requirement is minimum 820mm deep x 1120mm wide x 9mm thick fibre cement sheet (Bellis board or similar, with 

minimum of 300mm in front of 2 sides of glass.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Flue Connection to Heater 

 

The flue collar fitted to the unit is 5” – Inner diameter is tapered from 137mm and outer diameter is 148mm. 

The top flue connection requires either a 5” to 6” adaptor to fit within the top box, or the Austroflamm Flue damper (fits to the 

outside of the flue collar (ensure the connection is sealed with fire cement on the inside). 

If using the flue damper inside the top box, ensure the damper is set to 30 degrees from the horizontal (assuming a 4.6m 

flue height from the hearth). 

 

For rear connection, the rear flue blanking plate is swapped with the flue collar supplied on top of the firebox.  Use the top 

box with blanking cover to cover the unit.  Using the 5’ to 6” adaptor into the flue collar, have holes drilled through the cast 

flue collar into the stainless steel active so the flue is mechanically fixed, and seal with fire cement.   Connect to a wall 

penetration kit or a drop box with triple skin T-piece and flue as per normal with rear wall flue installation.  See pics on page 

8. 

 

 

 

Adaptor to flue inside the top box. 

 

 

 

 

 

 

 

 

Содержание Dexter 2.0 L

Страница 1: ...Benutzerhandbuch manual manuale manuel User instructions Dexter 2 0 ...

Страница 2: ...y air supply english Contents 1 Techn data 5 2 Important information 5 3 Correct operation of your stove 6 4 The most important spare parts overview 7 5 Special features 8 Guarantee 17 This instruction describes the Dexter left Fig 2 ...

Страница 3: ...ve Attention stove varnish is no rust prevention Make your children aware of this particular danger and keep them at a distance from the heating unit whenever it is in operation Only burn approved fuels and materials listed in the chapter Clean Burning The burning or placing of flammable or explosive materials like empty spray cans and such like into the firebox as well as the storage of such mate...

Страница 4: ...bre cement sheet Bellis board or similar with minimum of 300mm in front of 2 sides of glass Flue Connection to Heater The flue collar fitted to the unit is 5 Inner diameter is tapered from 137mm and outer diameter is 148mm The top flue connection requires either a 5 to 6 adaptor to fit within the top box or the Austroflamm Flue damper fits to the outside of the flue collar ensure the connection is...

Страница 5: ... must have its own dedicated flue The active flue must be 8 for the entire length of the flue and always less than 45 degrees from the vertical Replacement room air from outside equivalent to 160cm2 must be supplied into the room Flue Outlet Positions Minimum Flue Height as per AS NZS 2918 2018 NOTE Flue exit MUST also be as high as any nearby structure within a 6m Radius AS 2918 2018 ...

Страница 6: ...8 english Exter External Requirements Refer to AS NZS 2918 2018 Note All external air vents ceiling penetrations must be bird rodent proofed with permanently fixed screens Flue Collar Connection for Rear Flue ...

Страница 7: ...DING CODE OR CODES o WARNING APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS NZS 4013 2014 WHERE REQUIRED BY THE REGULATORY AUTHORITY I E THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING TESTED TO AS NZS 4013 2014 o ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED ...

Страница 8: ...rawer if necessary watch out for ambers Position the lever for the combustion air to the open AUF position see fig 4 Place 2 3 logs approx 1 0 kg in total crossways in the combustion chamber 1 with sufficient distance from each other min 2 cm on top of that place some softwood chippings 0 4 kg 2 and some ignition aid and light 3 see fig 3 Close the door We recommend to let the first load burn down...

Страница 9: ...e 5 720427 Vertical Keramott outside 6 720424 Vertical Keramott corner 7 720425 Vertical Keramott rear 8 720426 Keramott baffle plate 1 9 720428 720473 Grate 716408 Other parts Dexter L Dexter R Keramott numbering installation instructions Description No Part number Dexter L Part number Dexter R Door complete 13 720430 720476 Door handle 14 361089 Door glass short side 15 720433 Door glass long si...

Страница 10: ...ructions if secondary air is closed the door glass soots rather fast wood logs are too large keep to the max fuel quantity according to user s instruction operating temperature was not reached more fuel use dry wood 15 residual moisture attend air regulation stove does not get enough combustion air chimney draught not sufficient contact your chimney sweep elongate chimney draught metering stove is...

Страница 11: ...surface coatings lacquer glass and ceramics Conditions of the Guarantee 1 Your AUSTROFLAMM stove was installed by a certified professional and is operated in accordance with the operator s manual 2 Claims to the guarantee shall be subject to a completely filled out Guarantee Card and submittal of the original invoice issued by a certified AUSTROFLAMM sales agent IMPORTANT Our guarantee includes fr...

Отзывы: