© Austria Email AG
30
V1.0 1/2021
L5
Operation of the electric
heater due to low water
temperature
--, 1°C to 55°C
-- (off)
Setting of the time interval of the automatic thermal disinfection/safety heating
–
anti-legionella
protection:
to enter the parameter display, we shortly press the
and
key
simultaneously. For browsing through the menu we use the same keys individually (see chapter
Parameter display). Select parameter L2 and after a few seconds the set time interval is displayed (14
days). While the set time interval is displayed, the values can be freely changed (from 1 to 99 days)
by using the
or
key. 5 seconds after the desired value is selected the flashing of the
light indicator stops and the settings are saved. We recommend an interval of 14 days and not more
often, since the energy consumption is about 1/3 higher than when the HP is in normal operation.
Setting of the bivalent temperature (only in P5 programme):
to enter the parameter display, we
shortly press the
and
key simultaneously. For browsing through the menu we use the
same keys individually. Select parameter L1 and after a few seconds the pre-set switch-off
temperature (set to -5
°
C). While the set temperature is displayed, it can be freely changed by using
the
and
key (from -9
°
C to +30°C). 5 seconds after the desired temperature is set the
flashing of the light indicator stops and the settings are saved.
7
Dismantling and Removal
Taking into account the instructions for safe use and maintenance, the device as a whole has a
designated life span of at least 8 years. However, life expectancy of individual components is
variable, therefore they must be immediately replaced in case of malfunctions, wear and tear or
mechanical damages.
Replacement can only be carried out by using technicaly compatibe or original spare parts.
At the end of the life span of the heat pump, the entire device must be deposited into landfill for
industrial waste, according to the waste classification. Components harmful to the environment must
be deposited at collecting points provided for this purpose.
8
Maintenance
8.1
General
If these instructions for safe use and maintenance are followed, the heat pump will function without
any servicing procedures and additional maintenance.
ATTENTION
The device must be connected in accordance with the national
regulations.