© Austria Email AG
27
V1.0 1/2021
6.6
Settings
ID
Description
1
Indicator of operating mode
2
Temperature and parameter display
3
Button for mode selection.
4
Button for manual thermal desinfection and quick heating
5
Thermal desinfection and quick heating indicator
6
- Button for temperature and parameter selection
7
+ Button for temperature and parameter selection
8
Compressor start blockade indicator
9
Compressor minimal operating time indicator
Light indicators
Programme DESCRIPTION
☼
not
illuminated
not
illuminated
P0
Operation of the heat pump is switched off; only display of the
water temperature in the storage tank is active.
☼
illuminated
not
illuminated
P1
Heat pump is heating water to the set temperature with the
compressor only. If the inlet air temperature is too low, the
compressor is switched off for safety reasons.
Attention: In case of a defective air sensor, the error is
indicated on the display, but the heat pump continues with the
heating of water.
☼
not
illuminated
illuminated
P2
The water in the water tank is heated to the set temperature
by means of a heating boiler only.
Note: the ambient air temperature has no influence on the
operation.