© Austria Email AG
15
V1.0 1/2021
ATTENTION
The heat pump must never be installed in locations, where there may be
harmful substances present in the air, which could damage the device (stables,
storage rooms for hazardous substances, outdoors, etc.).
4.4
Technical Data
Product
Heat pump for DHW heating with air duct.
Type
WPA
Model
WPA 303 E-LF
WPA 233 E-LF
Heating capacity:
1830 W (3330 W)*
Power consumption:
440 W (1940 W)*
Max. power consumption:
560 W (60°C) (2060 W)*
El. heater:
1500 W
Voltage:
230 V a.c.
Max. additional power for circ.
pump:
300 W
COPt (EN16147; A15W55; XL)
3,0
2,9
Refrigerant:
R134a (0,9kg)
Max. water temperature:
60°C - 65°C (75°C)*
Required air flow rate:
500 m
3
/h
Protection class:
IPX1
Ambient air temperature:
+7 - +35°C
Water heater protection:
Mg-anode
Sound level:
56 dB(A)
El. protection
16 A, (230 V a.c.)
Max. allowed pressure in the WH:
1,0 MPa (10 bar) at 95°C
Max. allowed pressure in the heat
exchanger (heating water):
1,0 MPa (10 bar) at 110°C
Max. allowed pressure in the
cooling circuit:
2,3 Mpa (23 bar)
Heating capacity of the boiler heat
exchanger:
15 kW
Water connections:
G 1''
Circulation:
G ¾''
Air connections:
Φ
150 mm
WH volume:
300 L
225 L
Mass
175 kg
130 kg
Minimum room hight
2200 mm
2000 mm
* In case of an additional el. heater.