Sequence of operations
1. Start the fireplace with the remote, or press the display
panels “Mode Select” button (figure 49) to start the
fireplace manually. The display panel will energize, and the desired flame level will be displayed.
2. The inducer will activate and perform a safety test lasting 45 seconds. The ignition sequence will
initiate after this test.
3. The igniter (HSI) will energize and start to glow red
4. After 20 seconds, the gas valve will open and ignite the burner on high. The flame sensor will verify
the flame is present within six seconds and the green LED light on the control board will illuminate.
5. The gas valve will adjust manifold pressure and the inducer speed to match desired flame level.
6. Use the “Manual Flame Level Adjustment” buttons on the display panel (figure 49) or the remote
control to change the flame level setting
7. As the heater warms up, the circulating fan will
activate, starting on Low speed. The Low Fan “L” symbol will display when the fan turns on.
The table outlines the BTU input the
rate of the burner for each flame
8. As the Heater continues to operate, the speed of the circulating Fan will increase, and the symbols
for Medium (n) and High (H) will appear
FLAME LEVEL
REMOTE SIGNAL
MANUAL FLAME
LEVEL
NOT USED SLOWER ONE
MANUAL FLAME
LEVEL ADJUSTMENT
DOWN
CONDENSATE
PUMP
RESET INDICATOR
BACK LIGHT
FLAME PRESENT SLOWER SPEED
MODE
SELECTION
BUTTON
Figure 49
Archer
Flame Level BTU Input
5
20
4
17
3
15
2
12
1
10
Note: The entire ignition sequence takes approximately one minute, 15 seconds to complete.
Note: When changing from a low flame level to a higher flame level, the fireplace will automatically increase to
level 5 (High) prior to proceeding to the desired flame level. This is to ensure consistent operation.
Note: The fireplace will always ignite on Level 5 (High) prior to adjusting to the flame level on the
display panel.
27