11
Cooperation of the AURATON RT receiver with the
AURATON T-1 regulator and/or the AURATON T-2 thermometer
The operation of temperature regulation in the receiver is based on the binary algorithm
(on/off) using one or two sensor elements.
•
The AURATON T-1 regulator allows for setting and/or monitoring the temperature.
•
The AURATON T-2 thermometer provides information about the current temperature
only, without the capability of changing it manually.
A)
The manual setpoint – pairing the AURATON T-1 regulator with the RT receiver allows
for setting the temperature manually and controlling it in the location of the fastening
of the T-1 regulator.
B)
The remote setpoint – if the T-2 thermometer is additionally paired with the RT receiver,
the AURATON T-1 regulator retains the capability of temperature setting, however its
control is performed with the paired T-2 thermometer only. This feature allows for
regulating the temperature in a room other than the one where the AURATON T-1
regulator is placed.
An example: you want the temperature in the “children’s room” to be always at 22°C,
however you do not want children to be able to change it - in that room, you install
the T-2 thermometer, and the AURATON T-1 regulator in e.g. the kitchen. This way the
temperature in the “children’s room” will always be at 22°C regardless of temperature
fluctuations in the kitchen.
C)
The factory setpoint (20°C) – if the T-2 thermometer is the only device paired with
the RT receiver, it is not possible to set the temperature manually, and the RT receiver
maintains the factory temperature setpoint of 20°C.
NOTE!
1.
The sequence of pairing the AURATON T-1 regulator and the T-2 thermometer is very
important. If you want to maintain the remote setpoint, you must first pair the AU
-
RATON T-1 with the RT receiver, and then the T-2 thermometer. Reversing the pairing
sequence will cause automatic deregistering of the previously paired T-2 thermometer
and entering the mode of operation described in item A.
2.
The RT receiver can operate with one AURATON T-1 regulator and/or one T-2 thermom
-
eter only. Pairing a new regulator causes deregistering the previously paired regulator
and the T-2 thermometer. Pairing a new T-2 thermometer causes deregistering the
previously paired T-2 thermometer only.
3.
The T-1 regulator and/or the T-2 thermometer can operate with an unlimited number
of receivers, e.g. one regulator can simultaneously control two independent heating
devices.
Содержание T-1 RT
Страница 1: ...O W N E R S M A N U A L EN www auraton pl T 1 RT ...
Страница 16: ...www auraton pl ver 20190408 ...