background image

8

Pairing of the wireless AURATON RT controller with 

the AURATON RT receiver

Deregistering the regulator from the RT receiver

After the receiver is connected to the network, the receiver must be switched on by 

quickly pressing the power button (   ). If the device is switched on, the green power 

supply diode becomes illuminated and a single sound signal is emitted. In order to switch 

off the receiver, e.g. outside of the heating season, press the power button and hold it 

for 3 seconds until a double sound signal is audible and the green power supply diode 

is switched off and, consequently, the heating device is switched off.

In the event of an error during the pairing process, repeat steps 1 and 2. Should more 

errors occur, deregister all devices by executing the RESET function of the RTH receiver 

(see “RESET – Deregistering all devices paired with the RT receiver”) and attempt to pair 

the device again.

NOTE:

 One receiver can have only one temperature regulator assigned.

NOTE: The AURATON T1 wireless temperature regulator sold with the AURATON RT 

receiver is already paired. Devices sold separately require “pairing”. 
1. 

Pairing of the 

AURATON T-1

 controller with the 

AURATON RT

 receiver is initiated by 

pressing the right pairing button (green triangle –   ) a single sound signal is emitted – on 

the 

AURATON RT

 receiver and by holding it pressed for at least 3 s until the LED diode 

starts blinking with green light (double sound signal) – then the button must be released. 

The 

AURATON RT

 receiver waits for pairing for 120 seconds. After that time, it auto-

matically returns back to normal operation.

2. 

Press the pairing button (   ) placed on the rear side 

 

of housing and hold it for about 2 seconds. When LED 

diode ( ) will starts flashing red stop pressing the button. 

3. 

A properly completed pairing process is signalled by the 

LED on the AURATON RT receiver no longer flashing 

green and the receiver reverting back to normal 

operation.

1. 

Deregistering the 

T-1

 regulator from the RTH receiver is initiated by pressing the right 

deregistering button (marked with a red triangle –  ) on the RTH receiver and holding 

it for at least 2 seconds, until the LED starts flashing red, and then releasing the button

The AURATON RTH receiver waits for deregistering for 120 seconds. After that time, 

 

it automatically returns back to normal operation.

LED

Содержание T-1 RT

Страница 1: ...O W N E R S M A N U A L EN www auraton pl T 1 RT ...

Страница 2: ...efficient and interference free operation of the device LED LED s diode indicates the operation mode status of the controller 16A Thank you for purchasing this modern advanced microprocessor based temperature regulator AURATON T 1 RT AURATON H 1 Window handle sold separately AURATON T 2 Thermometer sold separately Optional elements of the system A window handle equipped with a position sensor and ...

Страница 3: ...alled lithium battery Life span of the battery is up to 20 years ATTENTION unchangeable battery diode indicating data transmission holes for fixing the wall mounting holder diode indicating pairing bottom indicating pairing with a receiver temperature setpoint knob temperature sensor setpoint of antifreeze temperature 7 C ...

Страница 4: ...ing devices with the RT receiver The LED light s green the output device is off the contacts COM and NC are closed The LED light s red the output device is on the contacts COM and NO are closed The LED flashes green the RT receiver awaits the device to be paired chapter Pairing the AURATON T 1 wireless regulator and the RT receiver The LED flashes red the RT receiver awaits the device to be deregi...

Страница 5: ...om the controllers The cables may be routed from the bottom of the receiver by breaking out holes in the mounting cover or from the back of the receiver if the cables are extended from the wall In order to connect the cables from the back the cover must be broken out 1 Take off the cover of the front part of the AURATON RT receiver by unscrewing the screws half way out 2 Connect the heating device...

Страница 6: ... g an assembly box a metal enclosure of a heater in order to not to interfere with its operation 1 Take off the covers from the front part of the controller see chapter Installation of the AURATON RT receiver 2 Mark the location of the holes for the fastening screws on the wall 3 In the marked locations drill holes with diameters appropriate for the diameters of the enclosed wall plugs 5 mm 4 Put ...

Страница 7: ...tion wall A place should be selected that is occupied most frequently pro viding undisturbed circulation of air Avoid heat radiating devices television set heater refrigerator etc or places exposed to direct sunlight In order to avoid vibration do not place the regulator in close vicinity of doors 1 Drill two 5 mm holes in the wall select the span of holes with a wall mounted holder enclosed to th...

Страница 8: ...s already paired Devices sold separately require pairing 1 Pairing of the AURATON T 1 controller with the AURATON RT receiver is initiated by pressing the right pairing button green triangle a single sound signal is emitted on the AURATON RT receiver and by holding it pressed for at least 3 s until the LED diode starts blinking with green light double sound signal then the button must be released ...

Страница 9: ...gnalled by the LED lit green In the event of an error during the deregistering process repeat steps 1 and 2 Should more errors occur deregister all paired devices see RESET Deregistering all devices paired with the RT receiver and attempt to pair the device again NOTE If after executing the RESET function the RT receiver is disconnected from power supply and then connected again the receiver will ...

Страница 10: ...ler heating device A simplified schematic of connecting the AURATON RT receiver with the heating device AURATON RT AURATON T 2 AURATON H 1 AURATON T 1 Additional system devices Setting the anti freezing temperature A controller is equipped with antifreeze mode This operation mode results in maintaining the room temperature amounting 7 C It is used during longer absence to prevent freezing of water...

Страница 11: ...e able to change it in that room you install the T 2 thermometer and the AURATON T 1 regulator in e g the kitchen This way the temperature in the children s room will always be at 22 C regardless of temperature fluctuations in the kitchen C The factory setpoint 20 C if the T 2 thermometer is the only device paired with the RT receiver it is not possible to set the temperature manually and the RT r...

Страница 12: ...maintained until closing This state will last until all windows are closed or trickle ventilated C The window is opened When you open a window equipped with the H 1 handle paired for longer than 30 seconds the relay in the AURATON RT receiver is switched off as is the connected heating device If all the assigned windows are again in a state other than opened the RT receiver returns to normal coope...

Страница 13: ...an error When you have only the H 1 handles and the T 2 thermometer paired with the RT receiver without the AURATON R25 RT regulator the RT receiver maintains a constant factory defined temperature of 20 C If you pivot any window equipped with the H 1 handle paired with the receiver a temperature of 17 C is maintained If you open any window equipped with the H 1 handle paired with the RT receiver ...

Страница 14: ...14 The AURATON RT receiver connection schematics CONTROL HEATING DEVICE e g a gas furnace 230V AC PROTECTIVE ELECTRIC HEATING DEVICE MAX 230V 16A ...

Страница 15: ... temperature is stable the regulator sends heart beat data every 5 minutes which is signalled with the LED blinking orange on the RT receiver In the event of a power outage the RT receiver will switch off When power is restored the heating device is switched on automatically and the RT receiver awaits a signal from the paired transmitters this signal should be received within 5 minutes of restorin...

Страница 16: ...www auraton pl ver 20190408 ...

Отзывы: