In  case  of  any  problems  with  communication  due  to  e.g.  excessive  distance  of

Auraton 8000

 from the regulators a repeater (signal amplifier) may be used.

ź

ź

ź

ź

ź

ź

Do not mount the controller in a metal cabinet, as it will  reduce (shield) its radio signal. 

It is assumed that a signal level below 20% requires the use of a repeater (LMS signal   

amplifier).

In some locations LMS signal propagation form wireless devices may be very difficult. In 

such  cases  a  repeater  (amplifier)  installed  between  the  transmitter  (device)  and 

Auraton 8000

 of will ensure correct proper operation of the system.

In extreme cases (large distances, metal barriers, more floors), it may be necessary to 

use more than one repeater to ensure the correct transmission of the signal.

More  information  about  repeaters  may  be  found  on  the  manufacturer's  website 

WWW.AURATON.PL

All connections shall be always made with disconnected power supply.
It  is  recommended  to  commission  the  installation  of  the  controller  to  a  specialized 

company.

15

Comments

Description of AUTO 24 function

NOTE: 

The  manufacturer  suggests  to  log  in  (pair)  at  least  one  1 

AURATON

  regulator, 

equipped  with  a  clock  (

e.g.  AURATON  2030  RTH

),  to  make 

AUTO  24

  function 

operate precisely.

AUTO 24

 function enables the user to control valves (heating), central heating pump and 

the relay which controls the furnace when communication with the controller fails due to 
discharged batteries or controller malfunction.
In this case 

AURATON 8000

 runs the same heating schedule for a given zone (the one with 

lost communication) as for the last 24 hours stored in the controller memory.

Description of voltage output of central heating pump

The central heating pump is turned on

, when any of heating zones is activated.

The central heating pump is turned off

, when no heating zone is activate.

A special anti-seizing algorithm overrides  any other control settings of the heating pump. It 
activates the pump for 15 seconds in the following cases:

After the controller detects the pump for the first time or each time after turning on 
the power supply and the relay.

Every 14 days after turning the pump is turned off, provided that A-8000 is turned 
on.

ź

ź

Description of potential-free output 
for controlling central heating furnace 

Controlling the relay (e.g. central heating furnace) 

Activating a regulation head in any zone results in activating the relay. 
The relay is turned off, when the heating is turned off in all zones.
This function operates simultaneously to the control of the output of central heating pump.

RESETTING the controller

In order to reset the controller to its default settings, proceed as 
follows:

1.  Press ON/OFF button 

 (a single acoustic signal will be 

emitted). The display will show a pick list. 

2. Use  controller

(up  &  down)  to  select  option 

Delete 

wireless  devices

,  and  then  press 

  button  and  keep  it 

pressed for 5 seconds.

3. Correctly  performed  RESET  operation  will  be  confirmed by 

acoustic signal.

[pow]

[kon] 

[KO]

"

"

OK

NOTE:   RESET of the controller results in deleting all paired  devices and user’s settings 

from the controller’s memory.

AURATON

8000

Cancel

Delete wireless 
devices 

<    English                         >

Turn off

Additional information

ź

ź

Left side of the controller

 is the place where antenna socket is installed (used in case of 

radio communication  problems ) and mini USB slot (for servicing purposes).

Right side of the controller

 is the place where fuse socket is located (4A, time-delay 

fuse).

Содержание AURATON 8000

Страница 1: ...Owner s manual www auraton pl 8000 AURATON 8000 ...

Страница 2: ...ystem It provides information about the window position to the controller The handle recognizes 4 window positions open closed pivotedandtrickle ventposition microventilation The handle transmits information to AURATON 8000 controller which activates the relay e g switching off a heater after opening the window or reducing temperature by 3 C when the window is pivoted inordertosaveenergy AURATON80...

Страница 3: ...ntral heating pump and a potential free outputthatmaybeusedforcontrollingcentralheatingfurnace AURATON 8000 communicates with wireless transmitters using modern transmission protocolLMS Description of AURATON 8000 Button of hot water circulation pump Multi functional controller left right up down OK button OK LCD display ON OFF button Button cover Buttons of heating zones 1 8 LED signalling ON OFF...

Страница 4: ...dbemadewithdisconnectedpower supply Central heating pump Power supply 230V 50HZ Terminal for hot utility water circulation pump Potential free relay contacts Terminals for heating zones head P c A ź ź ź N N N Mounting the controller The controller may be mounted on a wall using two fixing screws rawplugs with screws are providedwiththecontroller Cablesofthecontrollershallbefixedtothewallwithbracke...

Страница 5: ... user adds T 2 thermometer to the paired channel the actual temperature will be read from T 2 thermometer whereas only the set temperature will be read from the thermostat This allows the user to control the temperatureinaroomotherthantheroom wherethermostatisinstalled NOTE In the configuration with thermostat and T 2 thermometer it is important to keep the correct order of pairing the devices Alw...

Страница 6: ...tructions on activating pairing modeinaselecteddeviceisinitsmanual 3 Correct pairing of a LMS device is confirmed by a 1 second acousticsignal 4 When the button of the zone in pairing mode is shortly pressed thenthe pairing modeisturnedoff 5 Whenthe pairing modeisturnedoffinallzones A8000enters themodeofnormaloperation NOTE The pairing mode is automatically switched off 60 seconds after the last z...

Страница 7: ...D forselectedzonestopsblinking itmeansthatallLMSdevicesinthatzonehave beencorrectlydeleted When a LED of any zone continues to blink after deleting process it means that the controllerwaitsfordeletingotherLMSdevices NOTE Deletingprocessinselectedzoneturnsoffautomaticallyafter60s Deleting wireless devices LMS from a zone In order to delete all LMS from AURATON 8000 proceed as follows 1 PressON OFFb...

Страница 8: ...elayturnedoff LEDactiveat10 Central heating pump detected but turned off relayturnedoff LEDactiveat100 Centralheatingactive relayturnedon LEDinactive The heating zone has no LMS device paired no regulation head is connected to the connection witharespectivenumber LEDactiveat10 The heating zone has a LMS device paired and a regulationheadisconnected heatingisturnedoff LEDactiveat100 The heating zon...

Страница 9: ...ensure correct operation weekly programming it is necessary to pair at least one regulator with a clock e g AURATON 2025 RTH or AURATON2030RTH When only 24 h regulators without a clock e g AURATON 200 are paired then the pump operates only in interval mode operating time and break time may be programmed Hot water circuit MO F TU WE TH R SA SU 5 min 10 min Controlling the circulation pump in hot ut...

Страница 10: ... of the whole week settings ofonedayoftheweekmaybecopiedtoanother e g the time line form Monday bay be copied for Tuesday Wednesday ThursdayandFriday Tocopythetimelineformadayoftheweek proceedasfollows 1 Usecontroller up down toselectadayoftheweek tobe copied e g Monday andconfirmitbypressing button 2 After that changes may be introduced to the time line but they are not necessary Press again butt...

Страница 11: ...sing button 4 Then use controller left right to set the stoppage time and confirm it by pressing Now it is possible to set the stoppage time of the pump in minutes use controller up down Afterthisvalueisset confirmitbypressing 5 Now operation parameters of the circulation pump in the selected hour are set active rectangle KO KO KO KO KO troj KO KO KO a troj b button utton OK OK OK OK Hot water cir...

Страница 12: ...H At least one 1 temperature regulator equipped with a clock must be paired with the device If not this information will not be displayed Informs about pump operational status Pump turned on Pump turned off Empty field indicates that no device from this zone is paired with the controller Indicates activated relay heating of the zone 23 0 C 21 0 C Temperature in the zone Set temperature If temperat...

Страница 13: ...tivated relay heating of the zone Temperature in the zone Set temperature If temperature in the zone drops below the set value then heating of the zone will be activated Signal strength received from paired device Battery status of paired device Status of other devices paired with the zone here a wireless window handle AURATON H 1 Hysteresis History of relay operation for the last 24 hours graph 1...

Страница 14: ...central heating pump Thecentralheatingpumpisturnedon whenanyofheatingzonesisactivated Thecentralheatingpumpisturnedoff whennoheatingzoneisactivate A special anti seizing algorithm overrides any other control settings of the heating pump It activatesthepumpfor15secondsinthefollowingcases After the controller detects the pump for the first time or each time after turning on thepowersupplyandtherelay...

Страница 15: ...ionsshallbealwaysmadewithdisconnectedpowersupply It is recommended to commission the installation of the controller to a specialized company 15 Comments RESETTING the controller In order to reset the controller to its default settings proceed as follows 1 Press ON OFF button a single acoustic signal will be emitted Thedisplaywillshowapicklist 2 Use controller up down to select option Delete wirele...

Страница 16: ...and acoustic signal Automatic detection of connected heads central heating pump and circulation pump 8 30 W per zone controlling heads 230V up to 6 AURATON regulators heating pump 230V Disposal The devices are marked with a crossed wheeled bin In accordance with European Directive 2002 96 EC and the Act on Waste Electrical and Electronic Equipment this marking indicates that the device after compl...

Отзывы: