Switching the relay is synchronised with the wave of the 230 V mains voltage,
in order to ensure that closing and opening contacts of the relay occur
around the zero-crossing point. This prevents the occurrence of electric arc,
significantly extending the relay service time.
ź
The
AURATON RTH
receiver is equipped with a unique algorithm for
analysing the ON - OFF cycles. The entire heating cycle from the last 24 hours
is recorded in the memory of the
RTH
receiver. In the event of loss of
communication with the
AURATON 2030 RTH
regulator and/or the T-2
thermometer, the RTH receiver automatically executes the ON - OFF cycle
memorised during the last 24 hours. This provides the time for restoring
transmission (removing interferences) or fixing the
2030 RTH
regulator
and/or the T-2 thermometer without a significant deterioration of thermal
comfort conditions in the controlled spaces.
ź
The backlit LCD display with the capability of selecting one of three available
colours.
ź
The operating time counter of the
AURATON 2030 RTH
transmitter.
ź
Cooperation with optional devices (the
AURATON T-2
thermometer,
the
AURATON H-1
window handle).
Unique features of AURATON 2030 RTH
26
Additional information and notes
ź
The
AURATON 2030 RTH
regulator and/or the
T-2
thermometer must be
installed at least 1 metre from the
RTH
receiver (too strong signal from the
transmitters can cause interference).
ź
At least 30 seconds must elapse between switching the relay off and on.
ź
Data transmission from the
AURATON 2030 RTH
regulator to the receiver
occurs upon each change of the surrounding temperature by 0.2°C.
When the temperature is stable, the regulator sends heart-beat data every
5 minutes (which is signalled with the LED blinking orange on the
RTH
receiver).
ź
In the event of a power outage, the
RTH
receiver will switch off. When power
is restored, the heating device is switched on automatically, and the
RTH
receiver awaits a signal from the paired transmitters (this signal should be
received within 5 minutes from restoring power). After receiving the signal,
the
RTH
receiver resumes normal mode of operation.
ź
The
RTH
receiver cannot be placed in metal containers (e.g. an installation
cabinet, a metal enclosure of a heater), in order to not to interfere with
its operation.
ź
Switching off display backlight
- pressing any button for the first time
switches on display backlight (if only it is configured as active), pressing any
button for the second time invokes an action on the regulator, except for
pressing the
button in normal operating mode. Then the backlight is
switched on and the
INFO
function is invoked. When any button is pressed
and held for a while, the backlight is switched on instantly,
and the corresponding function is executed after the specific time of pressing
the button has elapsed.
OK/IN
The AURATON 2030 regulator connection
schematics
230 V
~
L
N
L N
NC
NO
COM
AURATON 2030
NC
NO
COM
AURATON 2030
Max. 230V
~
8 A
Max. 230V
~
heating
device
electric
heating
device
e.g. a gas furnace
Replacing batteries
If the low battery symbol ( ) appears on the display, it means that the battery
voltage has dropped below the minimal allowable level. In such an event,
replace the batteries as soon as possible.
NOTE
: In order to preserve the parameters programmed, duration of the
replacement operation must not to exceed 30 seconds.
NOTE
: When flashing low battery symbol appears on the display, the
backlight function is inactive. This feature designed to conserve
energy remaining in batteries.