Features 

Several useful functions and operating modes have been incorporated to adapt a variety of customer 
needs. 
• Room Temperature Display 
• Heater Operation Mode 
• Low Battery Indicator 
• On/Off Switch 

II INSTALLATION 

Select a suitable location for the thermostat.

The location of the thermostat can greatly affect its performance. If it is lacated at where circulate air
cannot reach, or exposed to direct sun light, it will not adjust the room temperature properly. To
ensure proper operation, the thermostat should be installed at an inside wall with freely circulating
air. Find a place where your family usually occupied. 

Avoid close to some heat generating appliance (e.g. TV, heater, refrigerator) or exposed to direct
sun light. Do not install near a door where the thermostat will suffer from vibration. For optimal
operation choose a mounting location: 

About 1.5 meter above the floor in an area with good air circulation. 

Away from drafts of dead air sports, air ducts, radiant heat from the sun or appliances, concealed
pipes and chimneys. 

Mounting 

Mounting the thermostat onto the wall. 

Remove completely the front housing of the thermostat by loosening the screws at the bottom.
(see picture) 

Содержание 1300

Страница 1: ...USER S MANUAL AURATON 1300 I INTRODUCTION This thermostat is designed to be used with electric gas or oil heating system Appearance LCD ...

Страница 2: ...e thermostat should be installed at an inside wall with freely circulating air Find a place where your family usually occupied Avoid close to some heat generating appliance e g TV heater refrigerator or exposed to direct sun light Do not install near a door where the thermostat will suffer from vibration For optimal operation choose a mounting location About 1 5 meter above the floor in an area wi...

Страница 3: ...TON 1300 thermostat can be used with single stage heating system Inside the thermostat three terminals which label COM common NC normal close and NO normal open would be found In most case COM and NO are used Temperature Span Span is the temperature difference between the turn ON and OFF temperature The factory pre set span is 0 5 C For example control temperature setting is 20 C The heater will b...

Страница 4: ...gently push the reset button TEMPERATURE 22 C CONTROL TEMPERATURE 20 C OUTPUT OFF III CONTROL TEMPERATURE At the normal operation mode the temperature could be set Push button to view the setting temperaturewhich was set last time When power up or reset the factory preset control temperature 20 C is shown Hold button about 3 seconds and the temperature indicator will flash one time Push button to ...

Страница 5: ...age of the battery decrease to certain level the LCD will be blank In this case the batteries should be changed as soon as possible to avoid any data loss V HEATER OPERATION Heater On Operation The heater will be turned on when the room temperature is lower than the programmed temperature and the Heater On Icon will be displayed as shown Output On Delay For safety purposes the thermostat has an au...

Страница 6: ...rce AAA 1 5V Alkaline battery x 2 Switching Relay Resistive load 5A at 250VAC Inductive load 3A at 250VAC Temperature Measuremen 0 40 C Temperature Accuracy 1 0 C Temperature Control 5 35 C Temperature Control Span 0 5 C Output On Delay 20 seconds Operating Temperature 10 C to 50 C non condensing Storage Temperature 30 C to 60 C Operating polluted condition Normal ...