Mark   the   holes’   position   and   align  the   wire   coming   from   the   wall  in  the   hole   beside   the
connectors.(see picture) 

Drill two holes and insert the plastic anchors carefully into the holes until they are flush with the 
wall. 

Fasten securely the thermostat to the wall with the two screws. 

Connecting the Wires 

The   AURATON   1300   thermostat   can   be   used   with   single   stage   heating   system.   Inside   the
thermostat, three terminals which label COM(common), NC(normal close) and NO(normal open)
would be found. In most case, COM and NO are used. 

Temperature Span 

Span is the temperature difference between the turn ON and OFF temperature. The factory pre-set
span is ±0.5°C. For example, control temperature setting is 20°C. The heater will be operated when
the room temperature drops to 19.5°C and will be turned off when the temperature rises to 20.5°C. 

Содержание 1300

Страница 1: ...USER S MANUAL AURATON 1300 I INTRODUCTION This thermostat is designed to be used with electric gas or oil heating system Appearance LCD ...

Страница 2: ...e thermostat should be installed at an inside wall with freely circulating air Find a place where your family usually occupied Avoid close to some heat generating appliance e g TV heater refrigerator or exposed to direct sun light Do not install near a door where the thermostat will suffer from vibration For optimal operation choose a mounting location About 1 5 meter above the floor in an area wi...

Страница 3: ...TON 1300 thermostat can be used with single stage heating system Inside the thermostat three terminals which label COM common NC normal close and NO normal open would be found In most case COM and NO are used Temperature Span Span is the temperature difference between the turn ON and OFF temperature The factory pre set span is 0 5 C For example control temperature setting is 20 C The heater will b...

Страница 4: ...gently push the reset button TEMPERATURE 22 C CONTROL TEMPERATURE 20 C OUTPUT OFF III CONTROL TEMPERATURE At the normal operation mode the temperature could be set Push button to view the setting temperaturewhich was set last time When power up or reset the factory preset control temperature 20 C is shown Hold button about 3 seconds and the temperature indicator will flash one time Push button to ...

Страница 5: ...age of the battery decrease to certain level the LCD will be blank In this case the batteries should be changed as soon as possible to avoid any data loss V HEATER OPERATION Heater On Operation The heater will be turned on when the room temperature is lower than the programmed temperature and the Heater On Icon will be displayed as shown Output On Delay For safety purposes the thermostat has an au...

Страница 6: ...rce AAA 1 5V Alkaline battery x 2 Switching Relay Resistive load 5A at 250VAC Inductive load 3A at 250VAC Temperature Measuremen 0 40 C Temperature Accuracy 1 0 C Temperature Control 5 35 C Temperature Control Span 0 5 C Output On Delay 20 seconds Operating Temperature 10 C to 50 C non condensing Storage Temperature 30 C to 60 C Operating polluted condition Normal ...

Отзывы: