background image

580.042b  GB 181004 

Description 
DigiFloor is an electronic thermostat for the regulation of 
floor heating. Mounting is done via a connection box. The 
thermostat is controlled wirelessly by the DigiHeat control 
unit. Time base for switching of load is 20 minutes.  
 
DigiFloor must be installed by an authorized electrician. 
 
If the floor sensor is not connected, the thermostat will use 
an internal air sensor for the regulation of room temperature 
(5-30°C). When the floor sensor is connected switching 
times are operational according to floor temperature. When 
the floor sensor is used the setpoint temperature should be 
considered as a guide figure only. Start off with a setpoint 
temperature of 20°C and adjust setpoint temperature until 
floor temperature is at your comfort level. NOTE! It takes 
hours for the floor temperature to stabilize. 
 
It is possible to use both the internal air sensor and floor 
sensor. The internal air sensor will regulate room 
temperature, while the floor sensor will limit the floor 
temperature to a maximum of 27°C. See paragraph sensor 
alternatives 
for details. 
 
Installation of DigiFloor 
Remove the control knob by pulling it towards you. (fig.1). 
Remove the bigger of the two screws below the control 
knob (fig. 2).  

Fig. 1

Screw

 

 

The front cover and the frame can now be removed. Turn 
the thermostat and complete the necessary connections 
(fig. 3). 

Heat element
Max 16A

Mains

230V +/- 10%

Floor

sensor

3

1

2

N

230V~4VA

5

4

16A

6

L

Fig. 2

 

The thermostat is then mounted inside the connection box. 

 

Screwhole

 

Fig. 4

 

TOP

 

 

 
Refit the frame and the front cover. Ensure that the arrow 
marked ”TOP” is pointing upwards as shown in fig. 4. 
Fasten the screw and put the control knob back in position. 
 
Note!

 DigiFloor is not equipped with a 2-pole switch, and a 

separate switch must be mounted if required by the 
particular installation. 
 
Note!

 DigiFloor is not equipped with an earth terminal. Any 

earth terminals from heat cable/mains must be connected 
by separate earth connector. 

 

Configuration of DigiFloor 
(see also user instruction for DigiHeat) 
First time configuration: 
When installed for the first time the thermostat’s green OK-
lamp will blink. This ‘blinking’ indicates the thermostat is not 
being programmed to receive information from the DigiHeat 
control unit. Put DigiHeat in configuration mode (see 
DigiHeat user instructions). Press the push-button marked      
on the thermostat. The OK-lamp will be lit and indicate that 
the thermostat is ready to receive information from DigiHeat. 
Reconfiguration: 
Hold the push-button on the thermostat down for about 10 
seconds until the OK-lamp starts to blink. Press the push-
button once. The OK-lamp will light after a few seconds 
indicating the thermostat is once again configured. The 
thermostat is now controlled by DigiHeat. 
 
Normal operation 
During normal operation the thermostat is controlled by 
DigiHeat. If the radio communication for some reason 
should fail, the thermostat will start regulation, according to 
its own temperature setting, after 1 hour. The green OK-
lamp will start to blink. When the radio communication is re-
established the DigiHeat control unit will automatically take 
over. 
 
Installing the floor sensor 
The floor sensor is put inside an installation tube embedded 
in the concrete floor. The tube should be sealed and placed 
as high in the concrete layer as possible. Only the enclosed 
floor sensor must be used. 
 
Placing of the thermostat with internal room sensor 
The thermostat should be placed on the wall 80 – 150 cm 
from the floor, where air can pass without obstruction. 
Direct sunlight should be avoided. The thermostat is not 
approved for outdoor use. 
 

LED indicators 
Red ON: Heat element ON. 
Red OFF: Heat element OFF. 
Green ON: Thermostat is configured. 
Green blinking: Unit not configured or radio signal is 
missing. 
 
Sensor alternatives 
Floor sensor: 

-

 

Constant floor temperature, typically in rooms 
where you walk barefooted. 

-

 

Floor sensor is automatically used when 
connected. 

-

 

Note that a temperature setting of 5-30°C on 
DigiHeat is equivalent to a floor temperature 
setting of 5-40°C. 

Internal sensor (air): 

-

 

Temperature setting on DigiHeat indicates 
required room temperature (5-30°C ). 

-

 

The floor temperature will depend on the room 
temperature. 

-

 

Internal sensor should be used if floor sensor is 
not possible. 

Two sensors: 

-

 

The wire (2) as shown in fig.5 must be cut for the 
thermostat to use both internal air sensor and floor 
sensor. Use cutting pliers (1). 

-

 

Internal air sensor (or sensor in DigiHeat) is used 
to regulate room temperature according to setpoint 
temperature. 

-

 

Maximum floor temperature is limited to 27°C. 
Typically for parquet or other temperature 
sensitive floor types. 

 
 

 

 
Local temperature control when DigiHeat is in comfort 
mode (

In some situations it might be preferable to let the user 
adjust the temperature on each heater, without having to do 
adjustments on DigiHeat. The thermostat has a built-in 
feature which will allow this. Normally each heater is 
controlled 100% by DigiHeat, and local control of 
temperature is not possible. Note that only comfort 

temperature (

) can be controlled on each heater, while 

setback ( ) and frost protection (OUT) is controlled by 
DigiHeat as normal. 
To activate this function, hold the       button down while the 
mains voltage is connected (fuse or switch). Then let go of 
the button when either the red or green light is blinking. 
When the red light is blinking it indicates that no local 
control of comfort temperature is possible. When the green 
light is blinking local control of comfort temperature is 

possible. To toggle between these two modes, push the 
button       once. The choice of mode must be done during 
10 seconds after activation. 
 
The local control of comfort temperature is well suited for 
offices, kindergartens, and rental housing, where it is 
preferred to let each user control the temperature during 
comfort hours (

). Note that when this function is activated 

the comfort temperature displayed on DigiHeat will not have 
any meaning. 
During normal operation one push on the button      allow 
for 3 hours cancellation of setback or frost protection 
temperature (for example during overtime hours).This 
function is only possible for version v.1.03 (see product 
label). 
 
Room thermostat 
The thermostat is prepared to receive measured 
temperature from DigiHeat. In such case the measured 
temperature from DigiHeat will be used to control the room 
temperature, and the internal sensor is no longer in use. 
See sensor alternatives. For DigiHeat 1 this will mean the 
internal sensor in DigiHeat will control room temperature. 
For DigiHeat 6+ the internal sensor can be activated for 
zone A by setting P1=1 (see instruction DigiHeat 6+). Note 
that DigiHeat must be placed in the temperature zone. This 
function is only possible for version v.1.03 (see product 
label). 
 
Technical specifications 
Operating voltage 

230V +/- 10% 

Maximum load  

16A (resistive) 

Isolation Class 

II 

Protection IP30 
Frequency 433,42 

MHz 

Temperature 

Internal sensor 5-30°C 

 

Floor sensor 5-40°C 

Temp. limit: 

Two sensors 27°C floor 

OFF-switch No 
Sensor type: 

NTC 100k

 / 25°C 

Measure (l h): 

70 x 70 x 55mm 

Building depth 

32mm 

El. number 

54 683 88 

 
 
 
DigiHeat room thermostat 16A 

2NC9 840 

 
 

 

GB 

Fig.5 

Отзывы: