![Aumuller EMB 7300 Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/aumuller/emb-7300-series/emb-7300-series_installation-and-commissioning-instructions_3016537023.webp)
23
Installation instruction
SHEV - Control Unit EMB 7300
Control Unit version
EMB 7300
5A-0101
5 AT
(batteries)
6,3 AT
(drives)
EMB 7300
10A-0101
10 AT
(batteries)
10 AT
(drives)
F1
F1
F2
F2
T
ROUBLSHOOTING
AND
R
EPAIR
/ F
USE
07
T
ROUBLSHOOTING
AND
R
EPAIR
All functions and system components that are important for the
SHEVS operation are constantly monitored for faults. A fault indication
signals the type of fault and, respectively, possible errors when connecting
system components (such as back-up batteries, detectors, drives) during
commissioning of the Control Unit.
The system software offers the possibility to check the
system behaviour in detail. Even when contacting our
support team on the phone it is helpful to have available
a computer with the system software installed.
The confi guration of the Control Unit using the software
has a signifi cant impact on the functionality of the indivi-
dual system components. Therefore, it might be necessary
to connect a computer provided with the system software
for precise testing.
The overview below details some of the possible faults and problem
cases and their causes. „Indicator
B
“ means the green operating indi-
cator which does not light up in case of a fault. The yellow “Indicator
S
” signals the type of fault. You fi nd a list of all indicators in chapter
„I
NDICATOR
AND
C
ONTROL
ELEMENTS
“.
!
Fault / Mal-
function
Possible cause and their solution
No indicator
lights up
• no power supply available or fuse F1 / F2 defective
Indicator „S“
fl ashes
• check power supply connection
Indicator „S“
blinks quickly
• back-up batteries are not correctly connected or are
not charged
Indicator „S“
has steady light
• open circuit or short circuit in manual fi re alarm
• faulty power monitoring
Indicator „S“
blinks slowly
• open circuit or short circuit in smoke detector line
• faulty power monitoring
Indicator „S“
blinks 2 times
• service required (indicator „B“ (green) lights up!)
Indicator „S“
blinks 4 times
• open circuit or short circuit in drive line 1
• faulty power monitoring
Indicator „S“
blinks 5 times
• only drive line 2,
cause of fault analogue to drive line 1
Indicator „S“
blinks 6 times
• EMERGENCY-CLOSE button (breakglass unit)
does not work properly and/or is not recognized
Drives do not
respond
• check fuse F2 / F3
• check drive connections based on assembly
instructions
• or, if the indicators (red / green) do not respond:
check ventilation control
Drives run incor-
rectly
• The indicators for the drive run direction (red / green)
must comply with the actual running direction.
Otherwise swap connections on terminal 1 and 2
• check drive connections based on their installation
instructions
Signal REL65 is
not recognized
• check relay plug-in card REL 65 for correct installationd
and connection
F
USES
Control Unit version
EMB 7300
5A-0102
5 AT
(batteries)
6,3 AT
(drive 1)
6,3 AT
(drive 2)
EMB 7300
10A-0102
10 AT
(batteries)
10 AT
(drive 1)
10 AT
(drive 2)
EMB 7300
20A-0102
25 AT
(batteries)
10 AT
(drive 1)
10 AT
(drive 2)
Control Unit version
EMB 7300
2,5A-0101
3,15 AT
(batteries)
3,15 AT
(drives)
3,15 AT
(primär)
F1
F1
F1
F1
F2
F2
F2
F2
F3
F3
F3
F3
1 32 33 35 36 37
+
+
+
+
-
a
a
N L
1
1
1
1
22
5
71
72
1 13 14 15 16 17 18 19
A
S
B
1
2 3
F1
US
B
A
Z
Reset
A
Z
A-
A+
F2
F3
US
B
US
B
1 32 33 35 36 37
1
1
1
22
5
71
1 13 14 15 16 17 18 19
A
S
B
A
Z
A
Z
1 32 33 35 36 37
A
Z
A
Z
Reset
1
1
2
2
3
3
A+
A-
N+
N-
F1
F2
F3
1 72
US
B
US
B
1
1
1
22
5
71
1 13 14 15 16 17 18 19
A
S
B
1 2 3
A+
A-
N+
N-
F1
F2
1 72
Reset
1 32 33 35 36 37
A
Z
A
Z
US
B