Installation instruction
SHEV - Control Unit EMB 7300
I
NSTALLATION
STEP
1:
C
ONNECTING
DRIVES
AND
VENTILATION
1
1
1
22
5
71
A
S
B
A
Z
A
Z
1 2 3
1
72
1
32
33 35 36
37
1
13 14 15 16 17
18 19
1
32 33 35 36 37
1234
56
2 3 4 5 6
1
ca. 1 s
=
=
-
+
+
-
1 2
Kl.
2
1
3
BK
BU
BN
BN
BU
BK
OG
1
1
1
22
5
71
A
S
B
A
Z
A
Z
1 2 3
1
72
1
32
33 35 36
37
1
13 14 15 16 17
18 19
1
32 33 35 36 37
A
Z
A
Z
1
32
33 35 36
37
1
32 33 35 36 37
1 2 3
1234
5
6
2 3 4 5 6
1
ca. 1 s
=
=
-
+
+
-
1 2
Kl.
2
1
3
BK
BU
BN
BN
BU
BK
OG
=
=
-
+
+
-
1 2
Kl.
2
1
3
BK
BU
BN
BN
BU
BK
OG
Connecting drives and ventilation:
Version EMB 7300
5A
-0102, EMB 7300
10A
-0102, EMB 7300
20A
-0102
Connecting drives and ventilation:
Version EMB 7300
5A
-0101, EMB 7300
5A
-0101-T, EMB 7300
10A
-0101
Terminal
Terminal
Terminal
Signal for
latching
04
!
!
!
!
!
!
!
!
!
BUS
BUS
Drive line
end module
Drive
24V DC
Drive
24V DC
Drive
24V DC
Drive
24V DC
Drive
24V DC
Drive
24V DC
M
M
M
M
M
M
Wind
Wind
Drive 1
Drive 2
Install drive line
end module at the last
drive in the line!
Install drive line
end module at the last
drive in the line!
Drives
EMB 7300
5 A
= max. 5 A (nominal current)
EMB 7300
10 A
= max. 10 A (nominal current)
EMB 7300
5 A
= max. 5 A (nominal current)
EMB 7300
10 A
= max. 10 A (nominal current)
EMB 7300
20 A
=
2
X
MAX
. 10 A
(nominal current)
SHEV release in case of fi re overrides ventilation.
No ventilation in the event of a mains power supply
failure (battery operation).
SHEV release in case of fi re overrides
ventilation. No ventilation in the event
of a mains power supply failure
(battery operation).
Automatic ventilation control *)
e.g. control system
NATURAL VENTILATION
Automatic ventilation control *)
e.g. control system
NATURAL VENTILATION
*) P
ay regard to the maximum life cycles
of the drives with automatic ventilation
control!
*) P
ay regard to the maximum life cycles
of the drives with automatic ventilation
control!
Plug-in terminals!
Remove for connecting!
Plug-in
terminals!
Remove for connecting!
or
or
COM
COM
OPEN
OPEN
CLOSE
CLOSE
max.
400 m
max.
400 m
max.
400 m
max.
400 m
max.
10 units
max.
10 units
OPEN
OPEN
Drive 1
Drive 2
Standard:
Deadman mode
Standard:
Deadman mode
CLOSE
CLOSE
CLOSE CLOSE
OPEN
OPEN
USB
USB
Rain
Rain
OPEN
OPEN
OPEN
CLOSE
CLOSE
CLOSE
Ventilation
Ventilation 2
Ventilation 2
Ventilation 1
Connections as
with ventilation 2
Ventilation 1
RM
RM
HSE
HSE
Connector
for fr
ont
push button
Connector
for fr
ont
push button
Color
BU =
blue
BN =
brown
OG =
orange
BK =
blue
Color
BU = blue
BN =
brown
OG =
orange
BK =
black
5 A
20 A
10 A
10 A
5 A
Drive line
end module
Drive line
end module
Ventilation
push button
Ventilation push button
Signal for
latching