4.
Place coupling [1] onto valve shaft [2] and secure against axial slipping by using
a grub screw [3] or a clamping washer and a screw with curved spring lock
washer [4]. Thereby, ensure that dimensions X, Y or L are observed (refer to
figure and table <Mounting positions for coupling>).
Figure 8: Examples: Fit coupling
[1]
Coupling
[2]
Valve shaft
[3]
Grub screw
[4]
Clamping washer and screw with curved spring lock washer
Figure 9: Mounting positions for coupling
Table 3:
Mounting position of the coupling within fitting dimensions according to AUMA definition
M100
M50
M25
Dimensions
[mm]
F10
F07
F10
F07
F05
F10
F07
F05
EN ISO 5211
4.5
4.5
3
3
3
3
3
3
X max.
4.5
4.5
2
2
2
2
2
2
Y max.
50
50
38
1)
/40
38
1)
/40
38
1)
/40
38
1)
/40
38
1)
/40
38
1)
/40
L max.
Thread with grub screw
1)
5.
Apply non-acidic grease at splines of coupling (e.g. Gleitmo by Fuchs).
15