15
Connecting terminals:
Clamping capacity, single wired,
fine-wired or multi-wired
≤
2.5mm
2
(AWG 14)
Multiconductor connection
maximum 2 x 1mm
2
3)
3)
Multiconductor connection is allowed at same cross-section and same conductor type, up to the
given value. In case of multi-wired conductors, wire-end sleeves are required. Pay attention to
EN 50019!
Acoustic data:
Signal tones
31 tones
Sound pressure
≤
119 dB(A) at 1 m distance
Angle, -6 dB at 1000 Hz
≤
130°
Operating conditions:
Mounting site
Indoors and outdoors
Operating mode
100% continuous operation
Operating position
any, although preferably such that the horn is
protected from intrusion of dust, rain water and
other pollution.
Ambient temperatures:
Operating
-20°C to +40°C
Transport
-25°C to +70°C
Storage
-25°C to +70°C
ÄAeÄnderungen vorbehalten
Subject to change without notice
Sous réserve de modifications
Sujeto a modificaciones
Ä
J. Auer Fabrik Elektrischer Maschinen Gesellschaft m. b. H.
Perfektastr. 102
A-1230 Wien
Telefon (00431) 813 82 20
Telefax (00431) 815 99 51
http://www.auer-signal.com
e-mail: [email protected]