![auer 950280 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/auer/950280/950280_installation-and-user-manual_3015800003.webp)
-
installer
HRC
70
35kW HIGH TEMPERATURE HEAT PUMP
manual
-
-
installer
HRC
70
35kW HIGH TEMPERATURE HEAT PUMP
manual
-
2
3
1.1 - Important information
1.2 - Safety advice and instructions
1 - PLEASE READ
IMMEDIATELY
These installation and operating instructions form part of the
appliances which they refer to.
In order for the warranty to be valid, they must be
read before using the appliance.
This manual must be safeguarded and passed on to
successive users for future reference.
It will be considered as evidence in case of litigation.
• The Heat Pump must only be installed outside.
• This appliance should not be used by: children under 8 years old;
anyone with reduced physical, sensory or mental capabilities; or
by anyone who has insufficient experience or knowledge of the
appliance; unless they are being supervised by someone who is
responsible for their safety and in possession of the operating
instructions of the appliance.
• Installation of the Heat Pump indoors is
strictly prohibited.
• The Heat Pump operates using an air temperature range of -20°C
to 40°C. When the temperature falls below -20°C, the installation
no longer heats using the Heat Pump, but using the back-up.
• It is FORBIDDEN :
- to operate the Heat Pump using air intake containing
solvents or explosive materials.
- to use air intake containing grease, dust, or aerosol particles.
- to connect vented exhaust hoods to the appliance.
• Use of the appliances are
FORBIDDEN
if the installation is not
filled with water.
• All work must be carried out by a qualified professional with the
appliance switched off.
• This appliance must be installed in accordance with national
electrical installation regulations.
Check that the appliance is equipped with a properly sized and
properly connected grounding cable.
This CE approved unit is in compliance with the following
standards:
- Low voltage 2006/95/CEE (standard EN 60.335.1).
- Electromagnetic compatibility 2004/108/CEE (standard EN
55014.1 / EN 55014.2).
• Any work on the refrigerant circuit must be carried out by a
qualified professional with a category 1 certificate of aptitude.
The release of refrigerant fluid into the atmosphere is prohibited,
the refrigerant fluid must be recovered before any work is
undertaken on the refrigerant circuit.
The high temperature Heat Pump absorbs the calories present in
exterior air, and transforms them into useful energy which is then
transferred to the heating water for your home. AUER cannot be
held responsible for any other usage of the appliance.
The safety advice and instructions present in this document must
be strictly respected.
Before making any connections to the installation, make sure the
appliances are compatible with the installation.
Before switching on the appliance, check that the network
voltage to be applied to the appliance is the same as the one on
the rating plate of the appliance.
Before undertaking any manintenance work, handling, or in the
case of the appliance not functioning or malfunctioning, always
disconnect the appliance from the power supply and seek advice
from a technician or specialist.
AUER cannot be held liable for damages caused by not following
the instructions provided, nor any problems or errors caused from
improper handling, improper installation, or misuse.
The installation and operating instructions are subject to change
without prior notice.
- It is the responsibility of the installer
and of the client to ensure that the
appliance is compatible with the power grid
before connecting the HRC
70
Heat Pump (see
the electricity provider information form in the
Appendix)
- The power grid impedance value must be less
than the Heat Pump impedance Z
max
value (see
§ «Connecting the HRC
70
Heat Pump to the
power supply»).
- If the electrical installation standards are not
respected there could be irreversible damages
to the HRC
70
Heat Pump which are not covered
by the manufacturer’s warranty.
RECOMMENDATIONS FOR
ELECTRICAL INSTALLATION
- Clean and flush the hydraulic heating
circuit before connecting the appliances
(Heat Pump and Pilot).
- The appliance only works when filled with
water. Never switch the appliance on if it is not
properly filled with water and purged of air.
- The filter valve ensures the protection of
the Heat Pump. An annual inspection of the
condition of the filter must be carried out.
- It is recommended to carry out periodic
inspections for sludge and limescale and to
clean when necessary. The appliance must
always be switched off before any cleaning is
undertaken.
- Always switch off the appliance before working
on any of the WWwelectrical components.
Caution: The fan may continue turning through
inertia even when the appliance is switched off.
Wait for the fan to stop before working on the
appliance.
- Never get water on the control components or
electrical parts. Always switch off the appliance
before cleaning.
RECOMMENDATIONS FOR
HYDRAULIC INSTALLATION