The trigger input is biased towards 
ground.  This keeps the unit in standby 
when nothing is connected. 

If you are not using master trigger-
ing, then you 

must

 install a short 

wire link from the +12V output 

to the trigger input. To put the unit into 
standby, remove the link.

To trigger ON with a contact closure:

 

Connect the contact closure between 
+12V and Trigger Input

To trigger OFF with a contact closure:

 

Connect a 1 kΩ resistor b12V 

and Trigger Input

 

Connect the contact closure between 
Trigger Input and GND

To use an external 12V trigger:

 

Connect the external ground to the 
Architect Model 2660  GND 

 

Connect the ex12V output 
voltage to the Architect Model 2660 
Trigger Input

Bus A and B Sections

7.  BUS A Input 

– This S/PDIF digital input 

uses a standard RCA coaxial connec-
tor. 

 

The digital signals are converted into 

two analog channels by the unit’s fine 

internal digital to analog converters. 
The two audio channels are then avail-
able to any zone that has its DIP switch 

4 set to Bus A (left), and switch 3 set to 
Bus (right).

 

The Signal Present LED lights when-
ever a signal is present at the Bus A 
input.

8.  BUS B Input 

– This pair of standard 

RCA coaxial connectors accepts 
line-level analog audio signals from 
source equipment such as CD players, 
DVD players, and MP3 players etc. The 
two audio channels are then available 
to any zone that has DIP switch 4 set 

to Bus B (right), and switch 3 set to Bus 
(right).

  The loop outputs allow a copy of the 

Bus B analog inputs to be sent out and 
shared with other units. The loop outs 
are directly wired internally to the Bus 
B analog inputs, and will pass signals to 
other units, even if the host unit is pow-

ered off.

  The Signal Present LED lights whenever 

a signal is present at the Bus B input.

Zone Section

 

  (all details are the same for each zone)

9.  Zone Level Control 

– This control sets 

the output level for the zone, inde-
pendent of the levels of all the other 
zones. Turn the controls with your 

fingers to make the adjustments. You 

may have to readjust the level if you 
change the source to that zone, from 
Bus A, Bus B, or Local.

10. DIP Switches 

– These five switches 

allow each zone to be set up individually:

DIP Switch Function Table

Switch

Label

Left (OFF)

Right (ON)

1

Mono

The zone is Stereo

The zone is Mono

2

PFM 40 Hz

The 40 Hz high pass 

filter is off

The 40 Hz high pass filter 

is on

3

Local/BUS

The zone is using the 
Local input

The zone is using the BUS 
input selected by switch 4

4

BUS A/B

The zone is using the 

BUS A input (S/PDIF), if 

switch 3 is set to BUS

The zone is using the BUS 

B input (Analog), if switch 

3 is set to BUS

5

Signal 
Sense

Signal sense is off

Signal sense is on

Switch 1. MONO:

 Left is Stereo, Right is 

Mono, and the inputs are summed.

Switch 2. PFM 40 Hz

 – This is a high-pass 

filter to reduce signal levels below 40 

Hz that are not reproduced well by 

small speakers. Left is off, Right is on.

Switch 3. LOCAL/BUS

 – Left selects the 

Local input as the zone’s input, Right 
selects the BUS Input, either A or B, 
depending on the position of switch 4.

Switch 4. BUS A/BUS B Selector

 – This 

switch is only active when switch 3 is 

set to BUS (right). Left selects BUS 
A (S/PDIF) as the zone’s input, Right 
selects BUS B (Analog).

Switch 5. Signal Sense

 – This switch 

controls whether the zone is always 
active when the master 12V trigger is 
active, or if the zone stays in standby 
until a signal is sensed. If signal sense 

is on (switch right) the zone will stay in 

standby until an audio signal greater 
than 5 mV is detected.  The zone will 
remain active whenever a signal is 
present. After two minutes with no 
signal detected, the zone will return to 
standby.

Wire Link

6

13 12

1

4

7

2

3

5

8

9 10

11

Содержание ARCHITECT 2260

Страница 1: ...ARCHITECT MODEL 2660 16 CHANNEL MULTI ZONE POWER AMPLIFIER Installation Manual...

Страница 2: ...es These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radi ate radio frequency energy and if no...

Страница 3: ...e as a loop output for example to share the source with an other Architect Model 2660 amplifier Each zone has its own local pair of analog input connectors Unparalleled Energy Efficiency Whether from...

Страница 4: ...ck mountable 2U form factor Removable rack ears Light weight 16 lbs Stackable with other Architect Model 2660 and Director Matrix M6400 models Signal sense independent for each zone Bus assignment ind...

Страница 5: ...ne Patio Zone Source Inputs Analog Source Outputs Digital Source Output Living Room Dining Room BUS A BUS B BUS B local local local local Family Room Using Bus Inputs to Create Larger Zones Using Loca...

Страница 6: ...re hazardous voltag es inside the unit Keep the rack ears in a safe place Ventilation This may be as good a time as any to have the talk about ventilation The Architect Model 2660 features cool runnin...

Страница 7: ...ypnotized press this switch in to turn off the LED ladders This switch does not affect the Power Protection or Zone Status LEDs 6 MasterTrigger TheTS 1 8 connec tors and the 3 pin block connector are...

Страница 8: ...l Present LED lights whenever a signal is present at the Bus B input Zone Section all details are the same for each zone 9 Zone Level Control This control sets the output level for the zone inde pende...

Страница 9: ...sing capa bility and a plethora of other really cool features please see our Director Matrix M6400 13 Speaker Outputs This 4 pin con nector allows easy connection of two speakers for stereo operation...

Страница 10: ...the unit for 3 to 4 minutes and reconnect to power b Disconnect all speaker wires If it still turns red and the unit has cooled something rather serious has happened inside the unit Call AudioControl...

Страница 11: ...ed at 60 Watts continuous adequate Just barely is the simple answer Go for one with a higher rating if you want a reliable long lasting system Though the Architect Model 2660 is rated at 65Watts it is...

Страница 12: ...200 Gain 27 dB Analog Input Sensitivity 1Vrms for full output level at maximum DAC Specifications 32 192 kHz sample rate 16 24 bit depth AC Power Requirements Standby 0 4Watts Idle 30Watts 1 8th powe...

Страница 13: ...ad this warranty then register the information at www audiocontrol com product registration and include your comments Our warranty has conditional conditions Conditional doesn t mean anything ominous...

Страница 14: ...s warranty Other than what we ve said we ll do in this warranty we have no obligation express or implied We make no warranty of mer chantability or fitness for any particular purpose Also neither we n...

Страница 15: ...28 Hurrah you are done Manual PN 913 128 0 Rev A Basic Cha Cha 2 2 START 9 8 5 1 4 3 7 6...

Отзывы: