background image

12

13

Installation Manual

Model 2660

ARCHITECT

Rear Panel

Rear Panel

Rear Panel Features

AC section   

When rack-mounting the unit, make 
sure that the power cord and the AC 
power switch remain readily acces-
sible.

1.  AC Input

 – Connect the supplied AC 

power cord securely to this input. Plug 
the other end into an AC mains outlet 
of the correct voltage rating for your 
unit. They are either 100 -120 VAC (50 

– 60 Hz) or 220 – 240 VAC (50 – 60 Hz); 

look at the check box to see how your 

unit has been configured.  The voltage 

setting is not user-settable. This unit 
is a class 1 device, do not defeat the 
safety ground connection or use a 
power cord that does not have the 
safety ground pin.

2.  AC Fuse

 – The main power supply fuse 

may be checked or replaced. Make 
sure that the power cord is unplugged 

from the AC mains first. Then use a 
flat-headed screwdriver to undo the 

fuse carrier from the fuse holder. 
Inspect the fuse and replace with the 
exact same type indicated on the unit. 

The use of any other type of fuse may 
lead to an unsafe condition. If the fuse 
blows again immediately, then unplug 

the power cord and contact our fine 

folks in customer service. Do not open 
the unit, as there are no user-ser-
viceable parts inside, and dangerous 
voltages exist.

3.  AC Power Switch

 – This switch shuts 

off the main AC power. Normally the 
only time you need to turn this off is 

if the system is going to be shut down 
for an extended period of time. Use 
the master trigger inputs to switch the 
unit between standby and on.

 

Also turn the power switch off during 

lightning storms, wind storms with 
frequent power outages, or closer to 
the time when the sun reaches the end 
of its red giant phase and you suspect 
it is about to go Supernova.

4.  Ground Isolation Switch

 – This switch 

selects the level of isolation between 
the audio signal ground and the AC 
earth ground. In normal operation this 
switch should be in the GND Ground 
position. If there is trouble with an AC 
ground hum, try the other two settings 
for the best operation. For safety, the 
chassis is always connected to the 
earth ground regardless of the switch 
setting. 

5.  Disable Front Panel LED Ladders

 – 

The front panel LED ladders show the 
output levels of each zone. If this is a 
distraction, or your pets keep getting 
hypnotized, press this switch in to turn 

off the LED ladders. This switch does 
not affect the Power, Protection, or 

Zone Status LEDs.

6.  Master Trigger 

– The TS 1/8” connec-

tors and the 3-pin block connector are 
used to turn on the unit or place it into 
standby mode. Any one of these three 
connections can be used as a trigger 
input. 

 

If no trigger voltage is present at any 
of these trigger inputs, then the unit 
will be in standby, with all zones mut-
ed. See the next page for important 
details if you are not using the master 
trigger.

 

LED indicator

 – This LED is blue when 

the master trigger input is active, and 

off when it is inactive.

 

3-pin connector

 – To remotely turn on 

the unit, use either a contact closure 
between the Trigger Input and the 
+12V output, or an ex12V 
trigger between the Trigger In and 
GND terminals. The +12V output is 
not designed to power other pieces of 
equipment or jump start your car. 

 

Pinout: 

 

GND Ground

 

+12V Output

 

+12V Trigger Input

 

1/8” TS mono jacks – These are wired 
in parallel to each other, and work in 
conjunction with the 3-pin connector. 
Either input can receive a +12V trigger 
which will turn on the unit. This will 
then allow the unused jack to output 
+12V that can be used to turn-on a 
second unit. If the 3-pin connector is 
used to trigger the unit, then both of 
the 1/8” jacks can be used to provide 
output triggers to other units.

 

Pinout:

 Tip

 = +12V Trigger Input  

 

 Sleev

e = Ground

 

Power Up Process: 

When a +3 to +12V 

signal is sensed at the trigger input of 
either of the 1/8” TS connectors, or the 
3-pin connector, the rear panel master 
trigger indicator LED will change from 

off to blue. All the zones will be held in 

standby for about 2 seconds until the 
power supplies have fully charged and 
performed their self-tests. During this 
short process, the front panel Power 
and Protection LEDs will be red. Once 
this is complete, the Power LED will 
turn blue and the Protection LED will 

turn off. 

 

Power Down Process: 

As soon as a 0V 

signal is sensed at the master trigger 
inputs, all zones will be muted and 
placed in standby, and the rear panel 
master trigger LED will change from 

blue to off. The front panel Power LED 

will remain on, as the main power 
supplies will be still energized.

 

If the master trigger Inputs remain at 0V 
for 2 seconds, the main power supplies 

will shut off; the front panel Power LED 

will change from blue to red. The Protec-

tion LED will flash red once during the 

power-down process.

6

13 12

1

4

7

2

3

5

8

9 10

11

Содержание ARCHITECT 2260

Страница 1: ...ARCHITECT MODEL 2660 16 CHANNEL MULTI ZONE POWER AMPLIFIER Installation Manual...

Страница 2: ...es These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radi ate radio frequency energy and if no...

Страница 3: ...e as a loop output for example to share the source with an other Architect Model 2660 amplifier Each zone has its own local pair of analog input connectors Unparalleled Energy Efficiency Whether from...

Страница 4: ...ck mountable 2U form factor Removable rack ears Light weight 16 lbs Stackable with other Architect Model 2660 and Director Matrix M6400 models Signal sense independent for each zone Bus assignment ind...

Страница 5: ...ne Patio Zone Source Inputs Analog Source Outputs Digital Source Output Living Room Dining Room BUS A BUS B BUS B local local local local Family Room Using Bus Inputs to Create Larger Zones Using Loca...

Страница 6: ...re hazardous voltag es inside the unit Keep the rack ears in a safe place Ventilation This may be as good a time as any to have the talk about ventilation The Architect Model 2660 features cool runnin...

Страница 7: ...ypnotized press this switch in to turn off the LED ladders This switch does not affect the Power Protection or Zone Status LEDs 6 MasterTrigger TheTS 1 8 connec tors and the 3 pin block connector are...

Страница 8: ...l Present LED lights whenever a signal is present at the Bus B input Zone Section all details are the same for each zone 9 Zone Level Control This control sets the output level for the zone inde pende...

Страница 9: ...sing capa bility and a plethora of other really cool features please see our Director Matrix M6400 13 Speaker Outputs This 4 pin con nector allows easy connection of two speakers for stereo operation...

Страница 10: ...the unit for 3 to 4 minutes and reconnect to power b Disconnect all speaker wires If it still turns red and the unit has cooled something rather serious has happened inside the unit Call AudioControl...

Страница 11: ...ed at 60 Watts continuous adequate Just barely is the simple answer Go for one with a higher rating if you want a reliable long lasting system Though the Architect Model 2660 is rated at 65Watts it is...

Страница 12: ...200 Gain 27 dB Analog Input Sensitivity 1Vrms for full output level at maximum DAC Specifications 32 192 kHz sample rate 16 24 bit depth AC Power Requirements Standby 0 4Watts Idle 30Watts 1 8th powe...

Страница 13: ...ad this warranty then register the information at www audiocontrol com product registration and include your comments Our warranty has conditional conditions Conditional doesn t mean anything ominous...

Страница 14: ...s warranty Other than what we ve said we ll do in this warranty we have no obligation express or implied We make no warranty of mer chantability or fitness for any particular purpose Also neither we n...

Страница 15: ...28 Hurrah you are done Manual PN 913 128 0 Rev A Basic Cha Cha 2 2 START 9 8 5 1 4 3 7 6...

Отзывы: