background image

16

17

Installation Manual

Model 2660

ARCHITECT

11. 12V Local Trigger

 – This TS 1/8” con-

nector allows each zone to be individu-
ally turned on or put into standby. 

 

The local 12V trigger takes priority 
over the signal sense circuit. Whenever 
a plug is inserted into the 12V trigger 
input jack, signal sense is disabled in 
that zone.

 

Note: The local 12V trigger can-
not activate a zone unless the 
master trigger is also activated 

or jumpered on. 

 

Pinout:

 Tip

 = Input  

 

 

 Sleev

e = Ground

Using a contact closure:

 

An open connection will set the zone 
to active.

 

Shorting the tip to the sleeve will set 
the zone to standby.

Using a 12V trigger source:

 

Connect the source ground to the 
sleeve.

 

Connect the source output to the tip. 
A voltage of +3V to +12V will set the 

zone to active; 0V will set the zone to 

standby.

Almost Done With The Rear Panel

Almost Done With The Rear Panel

 

Zone Active LED

 – This LED will turn 

blue whenever the zone is active. The 

LED will be off whenever the zone is in 

standby. 

12. Local Inputs

 – These are line-level 

analog RCA stereo inputs. These local 
inputs may be selected to play in this 
zone by setting DIP switch 3 to the left.

 

Local Inputs may not be bussed to 
other zones. For Matrix bussing capa-
bility (and a plethora of other really 

cool features) please see our Director 

Matrix M6400.

13. Speaker Outputs

 – This 4-pin con-

nector allows easy connection of two 
speakers for stereo operation, or one 
speaker for bridged mono operation.

 

Stereo Speaker Connection: 

 

Set the zone’s Dip switch 1 to the left 

(stereo). Note the polarity markings. 

The speaker impedance should 
be 4 Ohms minimum in stereo 
operation.

 

Bridged Mono Speaker Connection:

 

Set the zone’s Dip switch 1 to the right 

(mono). Note the polarity markings. In 

this mode, the input signals are com-
bined in mono, and the power from 
both channels is combined to drive a 
single speaker.

 

The speaker impedance should 
be 8 Ohms minimum in bridged  
mono operation.

 

To run two speakers in dual-mono, 
connect them in the same way as 
shown in the stereo speaker diagram 
above.

1

1

Speaker Connections

Establish a standard connection color 
code and stick with it. One conductor of 
the speaker wire is normally marked by 

a different color (silver versus copper) or 

there is a ribbing on one side. Typically this 
marked conductor is used for the positive 

(+) speaker leads. Really good wire has 

Positive and Negative printed right onto 
the wire jacket.
Match the polarity markings on the 
unit with the polarity markings on your 
speakers.
See the next page for some handy 
information about speaker and wiring 
impedance.

6

13 12

1

4

7

2

3

5

8

9 10

11

Содержание ARCHITECT 2260

Страница 1: ...ARCHITECT MODEL 2660 16 CHANNEL MULTI ZONE POWER AMPLIFIER Installation Manual...

Страница 2: ...es These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radi ate radio frequency energy and if no...

Страница 3: ...e as a loop output for example to share the source with an other Architect Model 2660 amplifier Each zone has its own local pair of analog input connectors Unparalleled Energy Efficiency Whether from...

Страница 4: ...ck mountable 2U form factor Removable rack ears Light weight 16 lbs Stackable with other Architect Model 2660 and Director Matrix M6400 models Signal sense independent for each zone Bus assignment ind...

Страница 5: ...ne Patio Zone Source Inputs Analog Source Outputs Digital Source Output Living Room Dining Room BUS A BUS B BUS B local local local local Family Room Using Bus Inputs to Create Larger Zones Using Loca...

Страница 6: ...re hazardous voltag es inside the unit Keep the rack ears in a safe place Ventilation This may be as good a time as any to have the talk about ventilation The Architect Model 2660 features cool runnin...

Страница 7: ...ypnotized press this switch in to turn off the LED ladders This switch does not affect the Power Protection or Zone Status LEDs 6 MasterTrigger TheTS 1 8 connec tors and the 3 pin block connector are...

Страница 8: ...l Present LED lights whenever a signal is present at the Bus B input Zone Section all details are the same for each zone 9 Zone Level Control This control sets the output level for the zone inde pende...

Страница 9: ...sing capa bility and a plethora of other really cool features please see our Director Matrix M6400 13 Speaker Outputs This 4 pin con nector allows easy connection of two speakers for stereo operation...

Страница 10: ...the unit for 3 to 4 minutes and reconnect to power b Disconnect all speaker wires If it still turns red and the unit has cooled something rather serious has happened inside the unit Call AudioControl...

Страница 11: ...ed at 60 Watts continuous adequate Just barely is the simple answer Go for one with a higher rating if you want a reliable long lasting system Though the Architect Model 2660 is rated at 65Watts it is...

Страница 12: ...200 Gain 27 dB Analog Input Sensitivity 1Vrms for full output level at maximum DAC Specifications 32 192 kHz sample rate 16 24 bit depth AC Power Requirements Standby 0 4Watts Idle 30Watts 1 8th powe...

Страница 13: ...ad this warranty then register the information at www audiocontrol com product registration and include your comments Our warranty has conditional conditions Conditional doesn t mean anything ominous...

Страница 14: ...s warranty Other than what we ve said we ll do in this warranty we have no obligation express or implied We make no warranty of mer chantability or fitness for any particular purpose Also neither we n...

Страница 15: ...28 Hurrah you are done Manual PN 913 128 0 Rev A Basic Cha Cha 2 2 START 9 8 5 1 4 3 7 6...

Отзывы: