background image

10

11

Installation Manual

Model 2660

ARCHITECT

Front Panel

Front Panel

Front Panel Features

1.  Power LED

 – This dual color LED indi-

cates when the unit is in standby, on, 

or off

Red:  The unit is in standby mode 

and is ready to be turned on 
via 12V triggering

Blue:  The unit is on

Green: Coffee brewed
OFF:  The unit is powered off 

2.  Protection LED

 – This red LED will 

illuminate briefly during turn on/off 

phases, and if a fault is detected in any 

amplifier or the power supply (such 

as overheating, over-current, or DC 

offset). If a fault is detected, then the 

unit will go into its protection mode to 
prevent any damage to loudspeakers, 
and to allow cooling. 

3.  Zone Status LED

 – This dual-color 

LED indicates when the zone is in fault 
mode, active, or in standby.

Red:  The zone has detected a fault, 

such as a DC offset or a load 

short circuit. 

Blue: The zone is active
OFF: The zone is in standby

4.  Zone Level LEDs

 – These three LEDs 

light from the bottom to the top 
depending on the zone’s output level 

(-33, -20, -10 dBFS). These LEDs can be 

defeated by engaging the rear panel 
switch  “Disable Front LED Ladders.”

5.  Rack Mount Ears 

– The unit comes 

supplied with removable rack mount 
ears. These allow the unit to be rack 
mounted in a standard 19” wide rack, 
with a 2U height. Use standard rack 
mount screws and washers to secure 
the unit in a rack. The unit does not 
have to be supported at the rear if the 

rack is located in a fixed location.

 

To remove the rack ears (making the 

unit 17” wide), first unplug the power 

cord, and then locate and undo the 
four screws securing each ear to the 
side of the chassis, and remove the 
ears. Replace the screws securely back 
into the chassis. Do not remove any of 
the other screws from the chassis or 
top cover. There are hazardous voltag-
es inside the unit. Keep the rack ears in 
a safe place.

Ventilation

 

This may be as good a time as any 
to have “the talk” about ventilation. 
The Architect Model 2660  features 

cool-running efficient switch mode 
power supplies and Class D amplifiers. 
It is still a 16 channel amplifier, and 

therefore requires good ventilation 

to properly cool.  The flow-through 

design of the chassis allows stacking 
of multiple Architect Model 2660 units 
(or mix and match with our Director 

Matrix M6400).  When rack mounting 

with equipment other than these two 
AudioControl units, please leave a 1U 
rack space above and below.

 

If the amplifier should overheat, a 

thermal sensor will put it into standby 
mode, allowing the heatsink to cool 

down. Once the amplifier has cooled 

to a safe operating temperature, 

the amplifier will reactivate. If this 

occurs often, identify the cause of the 
problem and take corrective action, for 
example:

Provide additional ventilation
Do not install in a sealed location 

with limited or no airflow

Install a fan in the rack

Make sure that the amplifiers are not 

overloaded with speaker impedances 
below the recommended minimum
Check that there are no short circuits 
in the speaker cables or speakers. 

Note: Each zone will shut off inde

-

pendently when a short circuit is 
detected.

1

2

3

5

4

LED Function Table

LED

Color Description

Red

The unit is in standby mode

Blue

The unit is on

Off

The unit is powered off, or all the lights are off in your town

Red

The unit has detected a fault and is in protect mode*

Off

The unit is operating normally, or it is powered off 

ZONE LEDs

Color

Description

Blue

-10 dBFS zone output level

Blue

-20 dBFS zone output level

Blue

-33 dBFS zone output level

Red

 The zone has detected a fault, or a smooth-jazz saxophone 
solo, and is in protect mode

Blue

The zone is active

Off

The zone is in standby

*The protection LED also comes on for a short time during 
power up or down

Содержание ARCHITECT 2260

Страница 1: ...ARCHITECT MODEL 2660 16 CHANNEL MULTI ZONE POWER AMPLIFIER Installation Manual...

Страница 2: ...es These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radi ate radio frequency energy and if no...

Страница 3: ...e as a loop output for example to share the source with an other Architect Model 2660 amplifier Each zone has its own local pair of analog input connectors Unparalleled Energy Efficiency Whether from...

Страница 4: ...ck mountable 2U form factor Removable rack ears Light weight 16 lbs Stackable with other Architect Model 2660 and Director Matrix M6400 models Signal sense independent for each zone Bus assignment ind...

Страница 5: ...ne Patio Zone Source Inputs Analog Source Outputs Digital Source Output Living Room Dining Room BUS A BUS B BUS B local local local local Family Room Using Bus Inputs to Create Larger Zones Using Loca...

Страница 6: ...re hazardous voltag es inside the unit Keep the rack ears in a safe place Ventilation This may be as good a time as any to have the talk about ventilation The Architect Model 2660 features cool runnin...

Страница 7: ...ypnotized press this switch in to turn off the LED ladders This switch does not affect the Power Protection or Zone Status LEDs 6 MasterTrigger TheTS 1 8 connec tors and the 3 pin block connector are...

Страница 8: ...l Present LED lights whenever a signal is present at the Bus B input Zone Section all details are the same for each zone 9 Zone Level Control This control sets the output level for the zone inde pende...

Страница 9: ...sing capa bility and a plethora of other really cool features please see our Director Matrix M6400 13 Speaker Outputs This 4 pin con nector allows easy connection of two speakers for stereo operation...

Страница 10: ...the unit for 3 to 4 minutes and reconnect to power b Disconnect all speaker wires If it still turns red and the unit has cooled something rather serious has happened inside the unit Call AudioControl...

Страница 11: ...ed at 60 Watts continuous adequate Just barely is the simple answer Go for one with a higher rating if you want a reliable long lasting system Though the Architect Model 2660 is rated at 65Watts it is...

Страница 12: ...200 Gain 27 dB Analog Input Sensitivity 1Vrms for full output level at maximum DAC Specifications 32 192 kHz sample rate 16 24 bit depth AC Power Requirements Standby 0 4Watts Idle 30Watts 1 8th powe...

Страница 13: ...ad this warranty then register the information at www audiocontrol com product registration and include your comments Our warranty has conditional conditions Conditional doesn t mean anything ominous...