Call Termination on FXO Devices
This section describes the device's call termination capabilities for its FXO interfaces:
Calls terminated by a PBX (refer to ''Call Termination by PBX'' on page
Calls terminated before call establishment (refer to ''Call Termination before Call
Establishment'' on page
Ring detection timeout (refer to ''Ring Detection Timeout'' on page
)
9.7.3.1 Calls Termination by PBX
The FXO device supports various methods for identifying when a call has been terminated
by the PBX.
The PBX doesn't disconnect calls, but instead signals to the device that the call has been
disconnected using one of the following methods:
Detection of polarity reversal/current disconnect:
The call is immediately
disconnected after polarity reversal or current disconnect is detected on the Tel side
(assuming the PBX/CO generates this signal). This is the recommended method.
Relevant parameters: EnableReversalPolarity, EnableCurrentDisconnect,
CurrentDisconnectDuration, CurrentDisconnectDefaultThreshold, and
TimeToSampleAnalogLineVoltage.
Detection of Reorder, Busy, Dial, and Special Information Tone (SIT) tones:
The
call is immediately disconnected after a Reorder, Busy, Dial, or SIT tone is detected on
the Tel side (assuming the PBX / CO generates this tone). This method requires the
correct tone frequencies and cadence to be defined in the Call Progress Tones file. If
these frequencies are not known, define them in the CPT file (the tone produced by
the PBX / CO must be recorded and its frequencies analyzed -- refer to Adding a
Reorder Tone to the CPT File in the Reference Manual). This method is slightly less
reliable than the previous one. You can use the CPTWizard (described in the
Reference Manual
) to analyze Call Progress Tones generated by any PBX or
telephone network.
Relevant parameters: DisconnectOnBusyTone and DisconnectOnDialTone.
Detection of silence:
The call is disconnected after silence is detected on both call
directions for a specific (configurable) amount of time. The call isn’t disconnected
immediately; therefore, this method should only be used as a backup option.
Relevant parameters: EnableSilenceDisconnect and FarEndDisconnectSilencePeriod.
Special DTMF code:
A digit pattern that when received from the Tel side, indicates to
the device to disconnect the call.
Relevant
ini
file parameter: TelDisconnectCode.
Interruption of RTP stream:
Relevant parameters: BrokenConnectionEventTimeout
and DisconnectOnBrokenConnection.
Note:
This method operates correctly only if silence suppression is not used.
Содержание mediapack MP-500
Страница 1: ...Document LTRT 12801 October 2009 User s Manual Version 5 8...
Страница 2: ......
Страница 22: ...SIP User s Manual 22 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 24: ...SIP User s Manual 24 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 290: ...SIP User s Manual 290 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 440: ...SIP User s Manual 440 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 564: ...SIP User s Manual 564 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 566: ...SIP User s Manual 566 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 573: ...Version 5 8 573 October 2009 SIP User s Manual 13 Technical Specifications Reader s Notes...
Страница 574: ...User s Manual Version 5 8 www audiocodes com...