Deployment of Two Devices for High Availability
The device supports 1+1 high availability, whereby two devices are deployed and
connected to the same broadcast domain/s. In such a setup, the same Ethernet port-pair
redundancy setup is done for each device. For example, if port-pair 5 and 6 are used for
Device "A", then Device "B" must also use port-pair 5 and 6, as shown in the figure below:
Figure
5-5: Cabling for High Availability (Example)
In High Availability, the two devices interconnect through their Maintenance interfaces,
using the same Ethernet Port Group.
Note:
For possible connections (including Tx / Rx settings) between the HA devices,
refer to the User's Manual.