7.2.2. Radio Signal Level Configuration
Select the
‘Radio Signal Level’ tab to configure radio signal level monitoring.
The definitions and explanations below also apply to the
‘Analog Audio’ tab.
Interactive graph
(1)
The primary feature of this tab is the interactive graph near the top of the window. This serves a dual
function, both displaying the readings gathered for that parameter, and allowing the user to change the
settings by dragging the lines associated with each level to a new value.
The thin black line represents the readings.
To change a
threshold
, the
hysteresis
or the
nominal level
move the mouse to the end of the
corresponding line, on the arrow
and click and drag.
The
Threshold
is the reference value. When the level overshoots it, the GOLDENEAGLE AM will trigger
an alarm or other action.
The ‘
Hysteresis
’ value establishes a level at which the unit will recover from an alarm state. In other
words, if the signal dips below the ‘Low’ threshold, the level must come up above the ‘Low’ threshold plus
the Hysteresis differential before the unit will cancel the alarm. This prevents the generation of dozens of
alarms and log events by levels that are fluctuating at or near the alarm thresholds. When the set value is
too high, the text box becomes red.
When the mouse is over an arrow symbol, the whole line and the corresponding value box turn red.
In section
(2)
:
Entered manually the desired value for various thresholds in text boxes.