GOLDENEAGLE AM 4.0.x user manual
– 07/2012
Page 74
Head Office
: Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928
– Fax +33 (0)5 57 928 929 –
–
www.audemat.com
APPENDIX B: DESCRIPTION OF SNMP MONITORING TABLES
Monitored value table:
OID
Name
Type
Description
1.3.6.1.4.1.5299.15.6.1.10.4.11.1.2.1.1
amreadingsvaluesidRow
INTEGER
Channel number (1)
1.3.6.1.4.1.5299.15.6.1.10.4.11.1.2.1.2
amreadingsvaluesidColumn INTEGER
Measurement # (2)
1.3.6.1.4.1.5299.15.6.1.10.4.11.1.2.1.3
amreadingsvaluesvalue
INTEGER
Current value
(1) The channel number corresponds to its row it the channel list (Monitoring page), starting from zero:
the first channel’s ID number is 0 and the 10
th
channel’s ID number is 9.
(2) Measurements are as follows:
0: RF level, value in dBuV x10
2: AF level, value in dBr x10
For instance, to read the RF level for channel 5, use a GET SNMP command on the OID:
1.3.6.1.4.1.5299.15.6.1.10.4.11.1.2.1.3.
4
.
0
Where .4 is the identifier of the 5
th
channel and 0 is the identifier of the RF measurement.
Monitored alarm table:
OID
Name
Type
Description
1.3.6.1.4.1.5299.15.6.1.10.4.11.2.2.1.1
alarmsvaluesidRow
INTEGER
Channel number (1)
1.3.6.1.4.1.5299.15.6.1.10.4.11.2.2.1.2
alarmsvaluesidColumn INTEGER
Alarm number (2)
1.3.6.1.4.1.5299.15.6.1.10.4.11.2.2.1.3
alarmsvaluesvalue
INTEGER
Current value (3)
(1) The channel number corresponds to its row it the channel list (Monitoring page), starting from zero:
the first channel’s ID number is 0 and the 10
th
channel’s ID number is 9.