In the Configuration section 

(1)

  Set the bitrate for high and low quality recordings. 

  Configure automatic deletion of recordings 

(‘Erase recorded files after’). 

 

In the scheduler 

(2)

, set up to 10 daily recordings. For each,  

  Enable by checking the box. 

  Set the frequency. 

  Set the starting time and the duration in minutes. 

  Set the recording quality. 

  Enter an optional complementary name.  

 

An  FTP  folder  is  automatically  created  in  the  GOLDENEAGLE  AM  when  a  recording  is  made.  The  folder 
name is the date (YYYYMMDD). All the recordings made on the same day are saved in this folder. 

The format of the name of the audio file is as follow:  

AB_YYYYMMDD_HHMMSS_TTT_FFFF_Comment.mp3 

AB

: bitrate 

 

AL: low bitrate 

 

AH: high bitrate   

YYYYMMDD

:

 Date of the beginning of recording 

HHMMSS

: Time of the beginning of recording 

TTT

:

 recording type 

 

PER: periodical 

 

MAN: manual 

FFFF

:

 frequency 

Comment

: file’s complementary name. 

 

Record files can then be retrieved by establishing an FTP connection to the GOLDENEAGLE AM, using an 
FTP  client  such  as  FileZilla.  Default  username  and  password  are 

record

’  ‘

record

’.  Those  values  can  be 

changed in the ‘Users’ page of the system configuration (see section 6.2.4). 

Содержание GOLDENEAGLE AM

Страница 1: ...audemat WorldCast Systems Group web www audemat com e mail contact audemat com GOLDENEAGLE AM User Manual Software version 4 0 x Date 2012 07 13 Audemat is a registered trademark...

Страница 2: ...k configuration using the embedded website 13 3 3 Installing the GOLDENEAGLE AM remote applications 14 4 THE INTERNAL WEBSITE 15 4 1 Product ID 15 4 2 Network 16 4 3 Download 17 5 REMOTE APPLICATION P...

Страница 3: ...1 Scan Management 51 8 2 Recording Management 51 9 ACCESSING READINGS 53 9 1 Analog Radio 53 9 2 AM Analog Scan 54 9 3 AM Market Scan 55 10 REALTIME MONITORING 56 10 1 AM Analog Radio 56 10 2 Spectru...

Страница 4: ...lity content over IP T1 E1 ISDN Leased Lines Ecreso who design a range of highly efficient transmitters for broadcast transmission technologies such as FM DAB DAB T DMB Both liquid and air cooled opti...

Страница 5: ...oftware key a modem supplied by Audemat is required to implement the option See section 6 2 8 See chapter 12 for software option activation 1 2 2 Hardware options Five slots are available in which I O...

Страница 6: ...he electrical network is not stable a power conditioner such as a UPS must be used The device must only be used with a plug that incorporates a protective ground contact To avoid any risk of electrocu...

Страница 7: ...ent overheating It is strongly recommended that the location is not subject to a high humidity level 70 and to avoid high salinity or chlorinated environments It is strongly recommended that the locat...

Страница 8: ...n power supply 100 250 VAC 50 60 Hz Power consumption 60 W 230 VAC Temperature Optimal performance temperatures Guaranteed working temperatures Storage 5 C 45 C 0 C 50 C 20 C 70 C Humidity 10 95 non c...

Страница 9: ...ity in the band 0 5 dB Precision 0 5 dB Span 60 kHz FFT calculated with the following parameters Type of FFT Blackman Harris Number of points 2048 Average 5 10 20 50 100 200 2 2 Network configuration...

Страница 10: ...com 2 3 List of the included accessories Check that all items are present in the box 1 power supply cable 1 straight Ethernet cable A 1 crossover Ethernet cable B 1 F SMA cable 1 BNC cable C 1 BNC F a...

Страница 11: ...the GOLDENEAGLE AM 2 5 Rear Panel Primary interface 192 168 0 100 Secondary interface 172 17 2 172 RJ45 straight Ethernet cable A for the network OR RJ45 crossover Ethernet cable B for a direct connec...

Страница 12: ...your PC in the 192 168 xx xx range so it is compatible with the IP address in the GOLDENEAGLE AM 192 168 0 100 The procedure varies depending on your operating system For this if using Windows 2000 or...

Страница 13: ...b browser Internet Explorer Mozilla Firefox and enter the unit s IP address login and password Default 192 168 0 100 Admin admin Click on Network in the left menu and update the primary interface IP a...

Страница 14: ...sy create scripts to automate and control inputs outputs and to manage alarms MasterView view and control your unit via custom views Do not install ScriptEasy or MasterView if more recent versions are...

Страница 15: ...audemat com 4 THE INTERNAL WEBSITE Links on the left side of the page enable easy navigation to the various pages of the site 4 1 Product ID The Product ID page lists the build versions of the various...

Страница 16: ...emat com www audemat com 4 2 Network IP configuration definition Current network status current network parameters Ethernet configuration mode The application can be configured for use with a static o...

Страница 17: ...omplete configuration of the unit system station and monitoring configuration ScriptEasy automation application for remote control of alarms sent by the GOLDENEAGLE TV management of I Os and creation...

Страница 18: ...been detected This method prevents useless alarms from being sent Measured Value Monitoring Parameters Alarms Values Recorded RF Level Nominal level Low threshold 1 Low threshold 2 High threshold hyst...

Страница 19: ...hort but frequent overshoots A time window and a number of acceptable overshoots during this time window must be set For instance if we do not want more than 5 overshoots within 2 minutes a counter wi...

Страница 20: ...following values channelType 8 AM frequency frequency in kHz x10 530 for 1710 kHz channelId row number of the station in the monitored channel list channelName station name alarmStatus integer indica...

Страница 21: ...actual times Channel 2 the error starts second 6 while the channel is monitored and ends second 11 when the channel is no longer monitored An error starts again second 18 and ends second 23 The monit...

Страница 22: ...33700 Bordeaux Merignac France Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com Depending on the version scanning is performed in either 3 kHz increments for the 9 kHz s...

Страница 23: ...he Network configuration page see section 7 2 5 The login and password can be modified on the Users configuration page see section 6 2 4 Default values are Admin admin for the administrator and Guest...

Страница 24: ...The application may take a few seconds to establish the connection Once connected the software will access data from the unit A simple user will be able to view most system unit and monitoring settin...

Страница 25: ...8 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 6 CONFIGURING THE GOLDENEAGLE AM Configuration is reserved for administrators 6 1 Set application preferences Display the options using...

Страница 26: ...them but not change anything Click the button Links on the left side of the widow allow the user easy access to the various settings 6 2 1 Product Identifiers The Product ID page lists the build versi...

Страница 27: ...month day and time hour minute second Set system time zone The user selects the geographical zone from the list Important to have this set correctly when using an NTP server Network Time Protocol NTP...

Страница 28: ...t audemat com www audemat com 6 2 3 Status The Status page gives a summary of the unit s vital parameters temperature available memory CPU load and available disk space This information may be request...

Страница 29: ...ftware application Administrator and Guest An Administrator has the rights to change any of the system parameters A Guest will be able to view measurements and alarms but will not be able to change an...

Страница 30: ...6 2 5 Network IP Configuration Ethernet configuration mode Both interfaces primary and secondary can be configured with a static or dynamic IP address DHCP Static Ethernet configuration If using a st...

Страница 31: ...p This function makes it possible for the unit to switch to the PPP interface to send alarms if the primary Ethernet interface eth0 doesn t function anymore i e if a reference address doesn t answer t...

Страница 32: ...s number of calls The user can limit the number of daily outgoing calls He she should put 0 if this limitation is not required The user can limit the number of hourly outgoing calls He she should put...

Страница 33: ...ization string is ATQ0V1H0 The Filter Callers function enables incoming calls to be filtered using Caller ID the incoming telephone line must have this service activated Filter Callers To add a new ac...

Страница 34: ...gnac France Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 6 2 8 Phone Alerts option This function activates DTMF phone alerts for ScriptEasy alarms Please refer to ch...

Страница 35: ...for example PPP in the case of a modem connection and the new port to use in the duplicate to field Each redirection line can be activated or disabled independently Once the configuration is done lock...

Страница 36: ...29 contact audemat com www audemat com The input and output interfaces of the router can be configured by the options Public interface Input and Private Interface output Once the configuration is done...

Страница 37: ...red are Webcam enabled activates or deactivates the webcam support Motion sensitivity sensitivity of the movement detection from 1000 to 32000 1000 is the highest sensitivity Mark motion location circ...

Страница 38: ...t enables the user to restart the application to reinitialize the parameters Reboot equipment restarts the entire unit Power off equipment enables the unit to be switched off remotely The unit cannot...

Страница 39: ...ilable that allow the user to configure the contents of the subject line and the first line of the body of the alarm e mail Any text entered in these windows will be included and there is a list of va...

Страница 40: ...sending test sends a Warm start trap to the destination s according to the trap settings 6 2 13 1 Supported SNMP versions The Unit SNMP agent is compatible wiht SNMPv1 and SNMPv2c versions GET and SE...

Страница 41: ...trap 6 2 14 Notifications SNMP Actions The user may replay traps that have not been acknowledged yet The user may also delete pending traps that have not been acknowledged yet Configuration depending...

Страница 42: ...s soon as the right conditions are met When a new notification appears the frozen notification is reactivated and a cycle of sending attempts begins again The alarm severity level can also be set a sp...

Страница 43: ...com 6 2 16 I O Log Set parameters for the I O log that the user can view from the application Status button Event log tab see section 11 2 Settings set recording frequency and length of time event log...

Страница 44: ...d activites Kennedy 20 avenue Neil Armstrong F 33700 Bordeaux Merignac France Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 6 2 18 Receivers On this page view informa...

Страница 45: ...mat com www audemat com 7 MONITORING CONFIGURATION Reserved for administrators Click to access the channel configuration pages 7 1 Managing channels 7 1 1 Adding New Channels to the Monitoring List Th...

Страница 46: ...erformed click Rescan to initiate a new scan 1 When the scan exists the channel to be added can be selected in the list of detected frequencies 2 The selected program frequency automatically appears y...

Страница 47: ...ut alarm will scan the station and keep track of the readings but will not send alerts on out of tolerance conditions Finally if you do not want this particular station to be a part of the regular mon...

Страница 48: ...ne represents the readings To change a threshold the hysteresis or the nominal level move the mouse to the end of the corresponding line on the arrow and click and drag The Threshold is the reference...

Страница 49: ...lation will only be recorded in the event log The Time out before alarm will configure a delay between an out of tolerance reading and the generation of an alarm which prevents transient and momentary...

Страница 50: ...mstrong F 33700 Bordeaux Merignac France Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 8 SCANNING AND RECORDING CONFIGURATION Reserved for administrators Click to acc...

Страница 51: ...M band at regular intervals or daily at the same time The triggering mode can be Disabled By interval scanning is launched at regular intervals ranging between 1 min and 24 h By hour scanning is launc...

Страница 52: ...tary name An FTP folder is automatically created in the GOLDENEAGLE AM when a recording is made The folder name is the date YYYYMMDD All the recordings made on the same day are saved in this folder Th...

Страница 53: ...n menu and select either view the last hour or last day s worth of readings You can also use the calendar to display any days readings over the last 30 days provided the unit was recording readings fo...

Страница 54: ...to display or hide each scan 2 Five levels of zoom are available Use to unzoom 3 Hover the cursor over the graph to display specific values for all 4 curves Before validating the scan alarm function s...

Страница 55: ...rance Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 9 3 AM Market Scan Select the AM Market tab or go to the Readings AM Market menu to view the market scan which giv...

Страница 56: ...io menu to instantaneously view levels in graphic form Simply enter the desired frequency it can be any frequency on the AM band even if it has not been previously configured 1 Then click to play and...

Страница 57: ...elect the channel from the list or enter directly the frequency and click 1 The Measure button in the Marker box 2 activates the measurement marker feature which allows you to set two markers by click...

Страница 58: ...m www audemat com The Display Options box contains 3 o a list control for setting the averaging of the readings o a list control for setting the frequency span of the display o Max Curve and Min Curve...

Страница 59: ...emat com www audemat com 10 3 AM Audio Monitoring Select the AM Audio Monitoring tab or go to the Realtime AM Audio Monitoring menu Simply enter the desired frequency After clicking you will get a sho...

Страница 60: ...aming menu to instantaneously listen to the audio stream Simply Select the player you wish to use the player embedded with the application or an external player Winamp or any player able to read m3u f...

Страница 61: ...com 11 VIEWING THE UNIT STATUS Click to view current alarms and event logs 11 1 Current Alarms Select the Current Alarms tab or go to the Status Current Alarms menu to quickly view current alarms All...

Страница 62: ...gs Three logs are available Realtime log list of current events The following information is listed sub system start and end time severity source event type and description The list is refreshed autom...

Страница 63: ...number of events to display Warning If the Max line count is 30 only the 30 first events will be listed this number is not a per page number We recommend you use the button It opens a dialog box that...

Страница 64: ...e 1 Plug in the modem 2 Insert the CD sent by Audemat upon purchase of the option the following screen will pop up 7 8 8 Close and restart the application 9 Once an option has been activated a new lin...

Страница 65: ...de With this mode all common pins are internally linked to the ground When a digital input is connected with the common this input s value switches to 1 otherwise it stays on 0 External power supply m...

Страница 66: ...ON 1 Digital input 1 2 Digital input 3 3 Digital input 5 4 Digital input 7 5 Digital input 9 6 Digital input 11 7 Digital input 13 8 Digital input 15 9 Common 10 Common 11 Common 12 Common 13 Not used...

Страница 67: ...two outputs NC normally closed and NO normally opened Schematic diagram When the relay is not in use com is linked to the NC output When the relay is activated com is linked to the NO output If your...

Страница 68: ...nd of the board Each circuit can support 5 A between 60 V and 60 V A 12 V power supply with a max current of 250 mA is available on pin 13 PIN NUMBER DESCRIPTION 1 COM1 2 NO1 3 NC2 4 COM3 5 NO3 6 NC4...

Страница 69: ...used by the unit Voltage V must be applied between one of the analog inputs and the ground Analog input module external connection diagram External connections on SUB D 25pts female connector situate...

Страница 70: ...1 5299 15 6 1 11 4 3 1 trapheartBeatOndateTime STRING YYYY MM DD HH MM SS 1 3 6 1 4 1 5299 15 6 1 11 4 3 2 trapsheartBeatOnseverity INTEGER Severity Trap Number 9 Trap Name trapsconfigChanged List of...

Страница 71: ...psScriptEasyInfochannel Associated channel 1 3 6 1 4 1 5299 15 6 1 11 4 7 9 trapsScriptEasyInfotransmitter Associated transmitter 1 3 6 1 4 1 5299 15 6 1 11 4 7 10 trapsScriptEasyInfonetwork Associate...

Страница 72: ...iptEasyManagerAlarmtransmitterId Associated transmitter Trap Number 41 Trap Name scanning List of variables included in the trap OID Name Type Description 1 3 6 1 4 1 5299 15 6 1 7 0 sysSystemType STR...

Страница 73: ...ed in the trap see trap 41 Trap Number 201 Trap Name analogAMRFLow2 List of variables included in the trap see trap 41 Trap Number 202 Trap Name analogAMRFHigh List of variables included in the trap s...

Страница 74: ...rting from zero the first channel s ID number is 0 and the 10th channel s ID number is 9 2 Measurements are as follows 0 RF level value in dBuV x10 2 AF level value in dBr x10 For instance to read the...

Страница 75: ...ow 3 Possible alarm values are 0 Beginning of error 1 End of error 2 Beginning of alarm 3 Intermittent error alarm 4 End of alarm 5 Alarm closed by hierarchy 6 Alarm reopened by hierarchy 7 Monitoring...

Страница 76: ...RE FOR RETRIEVING THE IP ADDRESS If you cannot connect to the embedded web site nor to the remote application use a PC to retrieve and update the GOLDENEAGLE AM s IP address Connect the unit to the po...

Страница 77: ...928 Fax 33 0 5 57 928 929 contact audemat com www audemat com Wait for 1 minute for the following screen Enter the password default password is admin and press Enter Select Display current IP configur...

Страница 78: ...t audemat com www audemat com APPENDIX D FOR FURTHER INFORMATION Please contact Head office Audemat 20 avenue Neil Armstrong Parc d Activit s J F Kennedy 33700 BORDEAUX MERIGNAC FRANCE Tel 33 5 57 928...

Отзывы: