Summary: Parameter and its initial setting.
Symbol Display
Description
Range
Initial
P
p
Proportional band (in 0.1 degree)
0-600
180
I
I
Integral constant (second)
0-900
700
d
d
Derivative constant (second)
0-300
40
AT
A
Auto-tune 0=off
1=on
0
Τ
Cycle rate (second)
1-100
2
SC
SC
Off set (degree)
-20~+20
0
Out
Output power reduction (%)
1-100
100
C-F
C-F
Temperature unit
°C or °F
°F
ΤΚ
Timer,
1=on,
0=off
1
SV
Set temperature
0-120°C,
32-248°F 140
Timer
Timer (hour)
0-99.9
99.9
Table 2. List of control parameters and its initial settings
Warranty
Auber Instruments warrants this controller to be free from defects in material and
workmanship for a period of one (1) year from the date of the original purchase when
utilized for normal household use, subject to the following conditions, exclusions and
exceptions. The sensor of the controller is warranted for 90 days.
If your appliance fails to operate properly while in use under normal household
conditions within the warranty period, return the complete appliance and accessories to
Auber Instruments
730 Culworth Manor
Alpharetta, GA 30022.
If the appliance is found by Auber Instruments to be defective in material or workmanship,
Auber Instruments will repair or replace it free of charge. A dated proof of purchase may
be required.
The liability of Auber Instruments is limited solely to the cost of the repair or replacement
of the unit at our discretion. This warranty does not cover normal wear of parts and does
not apply to any unit that has been tampered with or used for commercial purposes. This
limited warranty does not cover damage caused by misuse, abuse, negligent handling or
damage due to faulty packaging or mishandling in transit. This warranty does not cover
damage or defects caused by or resulting from damages from shipping or repairs,
service or alterations to the product or any of its parts which have been performed by a
13