Fig 6. Code 155 Parameter setup flow chart
Press and hold SET key for 4 second until Parameter Window displayed “LCK”. Release
the SET. The display will show “0”. Use “+” and “-“ keys to adjust the display to 155
(another pass code) and press SET.
Setting the calibration offset
. The parameter window will first show “SC “for a second
and then its value, Use “+” and “-“ keys to change the setting. When finished, press the
SET again to confirm the change. For example, if the temperature is 1 C too high during
calibration then use “-” to set the value to -1 to offset value.
Setting the output reduction.
The parameter window will first show “
OUt
“for a second
and then its value, Use “+” and “-“ keys to change
OUt
value to your desired limit value
and press SET.
Setting Celsius (C) or Fahrenheit (F).
When SET is pressed, the display will show “C-
F” and then its value of either “C” or “F”. Press “-” for C or “+” for F.
Turning Timer “OFF” or “ON”.
When SET is pressed, the display will show “ry” and
then “1” or “0”. Press “-” for “0” (off) and “+” for “1” (on). Press SET will return to Normal
mode.