         2021.06                                                                     

   

                                                       P4/4 

 

Power

Relay 

output

Reset

Pause

Stop

T1

Ta

Tb

Ta+Tb=T1

T2

T2

 
 

D. delay interval (delay off). 

 

Power

Relay 

output

Reset

Pause

Stop

T1

Ta

Tb

Ta+Tb=T1

T2

T2

T1

T2

 

E. cycle (delay on). 

 

Power

Relay 

output

Reset

Pause

Stop

T1

Ta

Tb

Ta+Tb=T1

T2

T2

T1

T2

 
 

F. cycle (delay off). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Auber Instruments Inc. 

5755 North Point Parkway, Suite 99, 

Alpharetta, GA 30022 

www.auberins.com 

Email: [email protected] 

 

Copyright ©  2021 Auber Instruments Inc. All rights reserved. 

No part of this datasheet shall be copied, reproduced, or transmitted in any 

way without the prior, written consent of Auber Instruments. Auber Instruments 

retains the exclusive rights to all information included in this document. 

 

Содержание JSL-74A

Страница 1: ...see note 1 on page 2 for details 8 Up key PAU key This key increases the value in the programming mode when timer is running pressing holding this key will pause the timer Once you release the Up key PAU key the timer will resume 9 RST key reset key When the timer is running the reset button will reset the timer If RUN parameter is set to RST pressing the button will start the timer after it has p...

Страница 2: ...see following section Definition of Programming Parameters Func timer operating function mode Available options are SdL single delay relay turns on at the beginning of relay delay time T1 OFDL relay turns on at the end of relay delay time T1 ONDL It will not change until the timer is reset or repowered again In Single Delay ON mode a special parameter for stop function STOP will show up in the par...

Страница 3: ...this example is also optional It is to show how to wire the output You can substitute it with any output such as a coffee grinder The output terminals 6 7 and 8 are from a C form internal relay It is a dry switch that does not provide the power by itself In this case the alarm is powered by the 120VAC The external switch connected to the alarm is for disabling the sound if needed 6 7 8 9 10 1 2 3 ...

Страница 4: ...top T1 Ta Tb Ta Tb T1 T2 T2 T1 T2 F cycle delay off Auber Instruments Inc 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Email info auberins com Copyright 2021 Auber Instruments Inc All rights reserved No part of this datasheet shall be copied reproduced or transmitted in any way without the prior written consent of Auber Instruments Auber Instruments retains the exclusive ...

Отзывы: