JSL-74A General Purpose Timer 

Version 1.1 (June, 2021) 

 

1. 

Overview

 

This JSL-74A timer can count from 0.01 second to 9999 hours. Operating 
function modes include single delay, double delay, and cycle delay.  It can 
count-down or count-up. This timer can be activated automatically when 
powering up, by front key pad, or via remote switch. 

 

2. Specification 

Timer range: 0.01 seconds to 9999 hours. 
Timer mode: single delay, double delay, cycle delay. 
Timer trigger: power on, front key pad, or remote switch. 
Timer accuracy: < 1 s/day. 
Power supply: 90 - 260 V AC or DC. 
Power consumption: < 2 W. 
Relay output: 7 A @ 240 VAC, 10 A @ 120 VAC and 24 VDC.  
Average relay life: 100,000 times at rated current. 
Operating temperature: 0 - 60° C. 
Humidity: 0-95% RH. 
Panel cutout: 44.5 x 44.5 mm. 
Outer dimension: 48 x 48 x 85 mm. 

 

3.

 

Front

 

Panel

 

1

3

2

4
5

6

7

8

9

10

 

Figure1. Front panel of JSL-74A timer. 

 

1. Time unit indicator: by default, the screen turns on when time format is 
MM:SS (Minutes: Seconds) or HH:MM (Hours: Minutes) and flashes when the 
timer is running; The screen turns off when time unit is M (Minutes) or S 
(Seconds). 
2. Timer indicator for seconds:  turns on when the time format is MM:SS or S; 
turns off when the time format is HH:MM or M. 
3. Timer indicator for minutes: turns on when the time base is HH:MM or M; 
turns off when the time base is MM:SS or S. 
4. RUN indicator: turns on when timer is running; blinks when timer is paused; 
turns off when timer is stopped. 
5. OUT indicator: turns on when relay is on; turns off when relay is off. 
6. SET key: press it momentarily to set T1 and T2; press and hold it for 3 
second will enter the programming mode. In programming mode, press it 
momentarily will go to next parameter setting. This key is disabled when timer 
is running. 

7. Down key / STP key: This key reduces the value in the programming mode; 
when the timer is running, press it to stop the timer. (For a special stop function 
in single delayed on mode, please see note 1 on page 2 for details). 
8. Up key / PAU key: This key increases the value in the programming mode; 
when timer is running, pressing & holding this key will pause the timer. Once 
you release the Up key/ PAU key, the timer will resume.   
9. RST key: reset key. When the timer is running, the reset button will reset the 
timer. If "RUN" parameter is set to RST, pressing the button will start the timer 
after it has powered up.  
10. LED digital display: during normal operation as a timer, the top displays the 
actual time; the bottom displays the preset value; in programming mode, the 
top displays the parameter, and the bottom displays the parameter value. 
 

4. Terminal Assignment 

6

7

8

9

10

1

2

3

4

5

NC

O

UT

NO

AC

90

~2

60

V

ST

P

PAU

R

ST

C

OM

 

Figure 2. Terminal assignment of JSL-74A.  

 

Details

1. Power for the timer needs to be connected to terminal 9 and 10. The voltage 
should be in the 90 to 260VAC range, like 110V AC or 240V AC.  
2. Terminal 6, 7, and 8 are for relay output. Terminal 6 is normally-closed (NC) 
contact. Terminal 8 is normally-open (NO) contact. Terminal 7 is common 
contact of the terminal 6 and 8. When the relay is energized (or when the OUT 
LED is on), terminal 8 connects to terminal 7, and terminal 7 disconnects 
terminal 6; When the relay is NOT energized (or when the OUT LED is off), 
terminal 6 connects to terminal 7, and terminal 7 disconnects terminal 8. The 

relay is a “dry switch” that does not provide power by itself. Please se

e the 

wiring examples in Section 7. 
3. Terminal 5 is the reset terminal that has the same function as the RST key in 
the front panel. Please see a note at the end this section.   
4. 

Terminal 4 is the pause/mute terminal that function the same as the “^/PAU” 

key in the front panel.   
5. 

Terminal 3 is the stop terminal that function the same as the “V/STP” key in 

the front panel.  
6. Terminal 1 is the common contact for the terminal 3/4/5. There are two ways 
to operate terminal 3, 4 and 5. 
6.a) Connecting a normally open (NO) momentary push button switch between 
the terminal (3, 4 or 5) to the COM (1). Please note, the function starts when 
you release (or open) the button of the switch, not when you press down the 
switch. See Figure 5. 

Instruction Manual

 

 

Содержание JSL-74A

Страница 1: ...see note 1 on page 2 for details 8 Up key PAU key This key increases the value in the programming mode when timer is running pressing holding this key will pause the timer Once you release the Up key PAU key the timer will resume 9 RST key reset key When the timer is running the reset button will reset the timer If RUN parameter is set to RST pressing the button will start the timer after it has p...

Страница 2: ...see following section Definition of Programming Parameters Func timer operating function mode Available options are SdL single delay relay turns on at the beginning of relay delay time T1 OFDL relay turns on at the end of relay delay time T1 ONDL It will not change until the timer is reset or repowered again In Single Delay ON mode a special parameter for stop function STOP will show up in the par...

Страница 3: ...this example is also optional It is to show how to wire the output You can substitute it with any output such as a coffee grinder The output terminals 6 7 and 8 are from a C form internal relay It is a dry switch that does not provide the power by itself In this case the alarm is powered by the 120VAC The external switch connected to the alarm is for disabling the sound if needed 6 7 8 9 10 1 2 3 ...

Страница 4: ...top T1 Ta Tb Ta Tb T1 T2 T2 T1 T2 F cycle delay off Auber Instruments Inc 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Email info auberins com Copyright 2021 Auber Instruments Inc All rights reserved No part of this datasheet shall be copied reproduced or transmitted in any way without the prior written consent of Auber Instruments Auber Instruments retains the exclusive ...

Отзывы: