![CTM LYNG 5648534 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/ctm-lyng/5648534/5648534_installation-and-user-instructions_2693923001.webp)
Timer, wireless
1
6
5
INSTALLATION
CTM Lyng AS is Norway’s leading manufacturer
and supplier of security products for the home,
assistive technology, energy efficiency, and light
and heating control for all building types under the
mKomfy
®
, mTouch
®
, Microsafe
®
and Centrol
®
brands.
We distribute our products through wholesalers.
We offer everything from product development to
production and distribution.
Our production facility in Vanvikan is equipped with some
of the most advanced machinery in Europe.
Verkstedvegen 19, 7125 Vanvikan, Norway
Tel:
+47 72 83 16 11
Email: [email protected]
Thank you for choosing a product from CTM Lyng AS
For more information, visit us at
www.ctmlyng.com
Installation and User instructions
0320
Art. N
o
.: 129
74_EN
Technical data
Dimensions:
Conforms to RS16
IP Code:
20
Battery:
CR2032
Battery life:
5 years in
normal use
RF:
868.100 MHz +5 dBm
Compatible with
“
v2
”
equipment, see page 2
RF range:
30 metres
NB:
It is best to carry out pairing and test the timer before
installation. Mount the switch directly on the wall or on the
outside of a standard wall box.
DIPSW
ANNUAL END USER TEST
The system owner/user must familiarise themselves with
the accompanying Installation and User Instructions at
installation, and is under an obligation to test that installed
equipment shuts off the water supply as required in the
Norwegian Insurance Approval Board (FG) test.
Function testing must be performed at least twice a year in
accordance with the Installation and User Instructions for
sensors and switch panels.
Back of
timer
ON
OFF
TIP
: Program all the units in a system before mounting. This will
make it easier to test the equipment.
Factory settings
:
1=ON 2=ON 3=OFF 4=OFF
*DIP 3 – Master switch function/Lock function
If DIP3=ON, only this switch panel can turn paired products back on if
they have been turned off with this switch panel.
Example
: A school kitchen wants to use a timer for all its cookers. All the cookers
also have a cooker guard. The teacher starts all the cookers by pressing the switch
panel (DIP3=ON) with the time set to 1 hour. All the cookers now have power for
1 hour. If the cooker guard cuts the power, the pupils can press the cooker guard
and get power back. After 1 hour, the switch panel turns all the cooker guard
sockets off. Now no pupil can turn the cooker on by pressing the cooker guard.
**DIP 4 – Time of choice
DIP1 and 2 must be OFF.
To change the time of choice, set DIP4=ON. Briefly pressing SW4 once
changes to the next time. The sensor acknowledges with the number
of beeps and flashes (LED3) for the time selected.
NB: Set DIP4 back to OFF once the desired time has been selected.
DIP 1
DIP 2
DIP 3*
DIP 4**
Time
ON
ON
ON:
Lock function
OFF:
Normal use
ON:
Set time of choice
NB! Must be
OFF when in
operation.
30 minutes
OFF
ON
1 hour
ON
OFF
4 hours
OFF
OFF
Time of choice**
SOUND
TIME
1 beep
5 min.
2 beeps
15 min.
3 beeps
20 min.
4 beeps
45 min.
5 beeps
60 min.
SOUND
TIME
6 beeps
90 min.
7 beeps
2 hours
8 beeps
4 hours
9 beeps
6 hours
10 beeps
10 hours
No. 5648534 / 6251645
SW4
LED3