background image

Owner’s Manual

and

Operating Instructions

Instructions for basic operation and installation

Printing Revision 5

Version 2.0

Содержание DPX16

Страница 1: ...Owner s Manual and Operating Instructions Instructions for basic operation and installation Printing Revision 5 Version 2 0...

Страница 2: ...G Camera Recording Priority 11 Camera Monitor Disable 12 Activity Detection Set Up 12 Display Sequence Set Up 13 Dwell Adjustment 13 Display Sequencing Format 13 Sequencing Format Screens 13 Alarm Set...

Страница 3: ...ecording speed record hours mode Proper VCR playback operation requires that the DPX16 be set up to multiplex at the rate which is compatible with your VCR recording speed see page 10 During multiplex...

Страница 4: ...grammable external Master Enable signal The DPX16 has sixteen alarm channels associated with the sixteen camera inputs Each alarm channel includes a programmable external input video Activity Alarm an...

Страница 5: ...DPX16 as shown above Refer to the Back Panel Connections and Video Termination Switches sections on the next page for proper connections and switch settings for your particular installation Power up...

Страница 6: ...ideo connector to the video input of the VCR You must use either the Composite video connection BNC or the S Video DIN connection In order for your DPX16 to work properly with the VCR DO NOT CONNECT C...

Страница 7: ...for the present mode except Zoom and another push of this button will deactivate the sequencing mode The default camera hold time is 3 seconds A button press during VCR Playback mode will cause a mul...

Страница 8: ...utton for selecting cameras and successive button presses will rotate through the available cameras Sequencing is initiated by pressing and holding the remote control s FREEZE button for approximately...

Страница 9: ...sages Time Date Setting Time and date for the on screen calendar and clock is set from this menu Selecting 1 Edits the hour of the day In 24 hour mode 0 through 23 is accepted as entered 2 Edits the m...

Страница 10: ...e video format and playback discriminator functions See the Advanced VCR options menu on page 20 VCR Selection Selecting 1 9 Selects a particular VCR from the displayed list The first two entries are...

Страница 11: ...e a limited set of front panel buttons the PIP button is used to input characters Using the legend any character can be entered in the present character location The VCR button is used to move to the...

Страница 12: ...Only The No Video indication will be given on the live display along with the blue background if the camera s signal is not present Activity Detection Set Up This menu is used to access and program A...

Страница 13: ...the display sequence format to suit your application You can program a specific selection of cameras for sequencing Selecting 1 Enters edit mode for dwell time see above 2 Enters Full Camera Call Up f...

Страница 14: ...ence 1 Cameras 12345678910111213141516 Enter Cameras you want displayed in the sequence Camera Select DISPLAY Accept and Return PIP Display Sequence 1 Background As is 2 Insert 12345678910111213141516...

Страница 15: ...camera s will be displayed and the alarming camera s will have an increased multiplexing rate When an alarm is disabled Off an alarm input will not affect any aspect of the VCR multiplexing the live c...

Страница 16: ...d return the display to the non edit mode as shown Note that the setting of the hours format in the Time and Date menu will determine the hours display in this menu Also note that when the system is i...

Страница 17: ...is the amount of time that the alarm event will be held so that the alarm camera image can be kept on the display screen and mutiplexed at a high frame rate to the VCR The maximum time for holding an...

Страница 18: ...camera number and type of alarm for each alarm event that has been stored The Alarm Log can store up to 100 alarm events at which point new alarm events continue to be stored and replace the oldest e...

Страница 19: ...e DISPLAY button until the ATV name appears This is not the preferred method of bypassing security since this step also returns all internal parameters and options to their factory defaults The securi...

Страница 20: ...same for record and playback Camera Switch Input For most applications the VCR delay table setting will provide the simplest setup and operation for multiplex recording For advanced applications such...

Страница 21: ...your remote control does not appear to work for any reason please perform the following steps before contacting the factory To program the remote control to work with the DPX16 1 Ensure that batteries...

Страница 22: ...performance can be obtained by setting up the one or two formats you actually plan to use according to the following basic guidelines What is the Delay Table The delay table is a list of pairs of num...

Страница 23: ...om delay table select the VCR Set Up menu option 2 from the Main Menu Then select Advanced VCR Options option 5 Select Edit Delay Table option 1 and the menu shown here will appear Note that before yo...

Страница 24: ...o the limitations introduced by these current limiting resistors The alarm connectors on the DPX16 are DB 15 15 pin connectors For ease of installation a breakout adapter is provided with the 16th ter...

Страница 25: ...m on pin 9 must not exceed 30 Vdc and the closed circuit current alarm active into pin 9 must be less than 50 mA The breakout adapter board is numbered compatibly with the DB 15 connector so the follo...

Страница 26: ...ton Lock n 0 sets front panel button lock OFF and n 1 sets button lock ON CM Call Monitor will cause the DPX16 to toggle between Normal and Call Monitor modes When in Call Monitor mode button commands...

Страница 27: ...000 Sony SVT 3050 Sony SVT L200 Sony SVT L400 Sony SVT S3100 Sony SVT 5050 short long Sony WatchCorder Toshiba KV5168A Toshiba KV6200A short long Toshiba KV7024 Toshiba KV7168A Toshiba KV7960A short l...

Страница 28: ...0 NTSC 720 X 576 PAL 4 2 2 256 Gray Levels 16 Million Colors Refresh Rate 30 Frames Per Second NTSC 25 Frames Per Second PAL Electrical Power 12 V AC 2 Amp Safety 110V 60Hz Power Supply UL Listed and...

Страница 29: ...ar where Year is a two digit representation of the year Conformity is defined as follows 1 No value for the current date will cause any interruption in operation of the product 2 Date based functional...

Отзывы: