14
Installation: mapping
Multiple target nodes
Multiple targets allow you to create a more
configurable mapping scheme which can segregate
storage into different iSCSI nodes within the iPBridge,
with each iSCSI target having its own set of access
criteria.
For example, if you have two servers and a library with
four tapes and a media changer, the default node
would provide both servers access to all tapes and the
media changer (default target mode).
If you configured multiple target nodes, you are able to
map some devices to one server and other devices to
the other server, requiring separate usernames and
passwords for access using various methods including
Access Control Lists, iSNS and CHAP authentication.
Consult with your network administrator and refer to
Exhibit 2.1-2,
iSCSI commands
on page 51 and the
Glossary
on page v of the Appendix.
Note
If you map actual storage to more than one
iSCSI target and a server has authorization for
both targets, the server could show duplicate
storage without any warning.
Automatically configure multiple targets
1
If you have not already, open an ExpressNAV
session. For instructions, refer to
Opening an
ExpressNAV session
on page 29
2
From the ExpressNAV main menu, click on the
Automatic Target Management
menu item on
the left side of the screen.
3
Click on the
Map each device to its own
target
button.
The iPBridge maps itself as a device at LUN 0.
A target name suffix is attached to the iqn of
each SCSI device such as
vendorid-devicename-xxx
•
vendorid
is the SCSI device vendor ID
•
devicename
is the SCSI device’s inquiry
device name.
•
xxx
is a device index
When the action is complete, the
iSCSI Target
Management
page appears.
If you are prompted to restart the iPBridge, go
to the
Firmware Restart
page and restart the
iPBridge.
Manually configure multiple target nodes
1
If you have not already, open an ExpressNAV
session. For instructions, refer to
Opening an
ExpressNAV session
on page 29
2
Click on the
Automatic Target Management
menu item on the left side of the screen.
3
In the
iSCSI Target Management
page, type
[name]
in the
Add an iSCSI target
box
The name is a suffix appended to the standard
IPBridge iqn name. The suffix name can be up
to 24 characters.
4
Click on the device map link of your target.
5
After the next mapping page opens, drag the
boxes representing SCSI devices to the LUNs
you want.
6
Click
Submit
.
7
Repeat from
Step 3
for each node you want to
configure.
8
If you are prompted to restart the iPBridge, go
to the
Firmware Restart
page and restart the
iPBridge.