27 ATTO Technology FibreBridge Installation and Operation Manual
7.1.8 Maintenance commands
The CLI commands outlined in this chapter may be used to get information or perform functions which
are used in a variety of situations with the ATTO FibreBridge
TM
.
CLI commands are case insensitive (upper and
lower case allowed anywhere).
Commands generally follow a standard format:
[Get | Set] Command [Parameter 1 | Parameter 2]
followed by the return or enter key
FibreBridgeModel
Reports model information about a specific FibreBridge
Action: none
Information: get FibreBridgeModel
Returns:
FibreBridge 1190
8
2001 ATTO Technology, Incorporated
Firmware version mm..mm release date mm.dd.yyyy, hh:mm:ss
Build zzzz
FirmwareRestart
Causes the FibreBridge to reboot, then re-initialize its firmware.
Actions: FirmwareRestart
Information: none
SerialNumber
Reports the FibreBridge serial number which is unique for each FibreBridge. The serial number tracks the board throughout its life and should not
be changed for any reason.
Limits: set form requires operator privileges
Actions: set SerialNumber
Information: get SerialNumber
Verbose return:
Part Identifier: PPPPPPP Sequence Number: nnnnnn
MaxEnclTempAlrm
Sets/displays the maximum enclosure temperature alarm of the unit in degrees Celsius. If the temperature of the FibreBridge rises above the maxi-
mum MaxEnclTempAlrm, thermal control event handling occurs.
Limits: valid entries are between 0 and 70 degrees and
above the current minimum enclosure temperature alarm
Default: 70
o
C
Actions: set MaxEnclTempAlrm [0-70]
Information: get MaxEnclTempAlrm
SaveConfiguration
MinEnclTempAlrm
Sets/displays the minimum enclosure temperature alarm of the unit in degrees Celsius. If the temperature of the FibreBridge falls below the mini-
mum MinEnclTempAlrm, thermal control event handling occurs.
Limits: valid entries are between 0and 70 degrees and
below the current maximum enclosure temperature alarm
Default: 0
o
C
Actions: set MinEnclTempAlrm [0-70]
Information: get MinEnclTempAlrm
SaveConfiguration
ScsiPortReset
Resets the specified SCSI bus.
Actions: ScsiPortReset [sb]
Information: none
Temperature
Returns the current internal temperature of the unit in degrees Celsius.
Actions: none
Information: get Temperature
Содержание FibreBridge 1190E