21 ATTO Technology FibreBridge 1190E Installation and Operation Manual
7.1.4 SCSI configuration commands
The SCSI ports are configured with default settings but may be customized to your specifications using
the CLI commands in this section.
CLI commands are case insensitive (upper and
lower case allowed anywhere).
Commands generally follow a standard format:
[Get | Set] Command [Parameter 1 | Parameter 2] followed by
the return or enter key
ScsiInitID
Specifies the SCSI initiator ID to be used on the specified SCSI port. All maps coinciding with the user-specified ScsiInitID must be set to offline
and will become invalid upon issuing this command
Limits: [0-15] wide [0-7] narrow
Action: set ScsiInitID [sb [0-15] ]
Information: get ScsiInitID
SaveConfiguration
ScsiPortBusSpeed
Controls the transfer rate at which the FibreBridge will attempt to negotiate with its SCSI devices.
Limits: Fast SCSI, Ultra SCSI, Ultra 2 SCSI (valid only if
FibreBridge has LVD-capable SCSI ports)
Default:
Actions: set ScsiPortBusSpeed [Port Number [ fast|
ultra| ultra2]
Information: get ScsiPortBusSpeed
SaveConfiguration
ScsiPortList
Returns a list of available SCSI ports and their current status
Limits: valid status values are OK and Failed
Action: none
Information: ScsiPortList
ScsiPortResetOnStartup
Specifies whether the SCSI port should be reset on power-up or not
Limits: [enabled | disabled]
Default: enabled
Action: set ScsiPortResetOnStartup [sb [enabled |
disabled] ]
Information: get ScsiPortResetOnStartup [sb]
SaveConfiguration
ScsiPortSelTimeout
Indicates the time, in milliseconds, that the bridge waits for a response from a SCSI device on the selected port after a selection request. Setting a
long selection time-out value can result in the host generating system time-out.
Limits: [256| 128|64|32|16|8|4|2|1]
Default: 64ms
Action: set ScsiPortSelTimeout [sb [256 | 128 | 64 | 32 | 16
| 8 | 4 | 2 | 1]]
Information: get ScsiPortSelTimeout [sb]
SaveConfiguration
ScsiPortSyncTransfer
Specifies whether synchronous SCSI transfers should be negotiated with devices on the specified SCSI port.
Limits: [enabled | disabled]
Default: enabled
Action: set ScsiPortSyncTransfer [[sb [enabled |
disabled] ]
Information: get ScsiPortSyncTransfer [sb]