![attas Gamma 60 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/attas/gamma-60/gamma-60_translation-of-the-original-operating-instructions_3005370027.webp)
26 / 147
Version 1.0
GAMMA 60 / 80
The garage door operator has the following
safety equipment. These cannot be removed and
their operation cannot be impaired.
• Automatic power shutdown (shutdown force) in the
"CLOSED" and "OPEN" functions
• Connection for additional safety equipment
• Obstacle detection
• Emergency release (see M7, page 115)
• See A1 and A4 on pages 110 and 111.
• Install grounded socket (10 to 50 cm away from drive
head).
• For assembly of garage door operator see M1 to M8,
beginning on page 111 (similar images).
• For the assembly of optional additional devices see
Section 16.
Once assembly is complete
• Ensure that the door is attached to the garage door
• Establish mains connection, self test is performed,
LED (1 green) flashes.
• Teach in garage door operator (see Section 11).
• Teach in hand-held transmitter (see Section 12).
• Perform safety check (see Section 14).
WARNING: No protection is provided by
obstacle detection while the garage door
operator is being taught in!
Do not press any other buttons during the
teaching in process.
A) Preparation
• If necessary, attach door to the garage door operator
and disconnect mains plug, where required.
B) Activating teach-in mode
• Insert mains plug, self test is performed, LED (1
green) flashes.
• Once the self test is finished (LED (2 red) flashes
slowly), press and hold the CANC button (5).
• At the same time, press and hold the TEST button
(6), until LED (1 red) and LED (2 green) flash rapidly.
• Wait until both LEDs (1 red and 2 green) flash slowly.
Teach-in mode is activated.
C) Teaching in door OPEN position
• Press and hold TEST button (6), until the door is
approx. 10 cm before the OPEN end position.
• Move door in button operation, using TEST button
(6), to the desired OPEN end position.
• Press the CANC button (5), LED (1 red) briefly lights
up to confirm that the door OPEN position has been
stored.
If LED (1 red) does not light up, disconnect mains
plug and start teach-in process again (starting
from A).
D) Teaching in door CLOSED position
• Press and hold TEST button (6), until the door is
approx. 10 cm before the CLOSED end position.
• Move door in button operation, using TEST button
(6), to the desired CLOSED end position.
• Press the CANC button (5), LED (1 red) briefly lights
up to confirm that the door CLOSED position has
been stored.
If LED (1 red) does not light up, disconnect mains
plug and start teach-in process again (starting
from A).
E) Teaching in forces
• Briefly press TEST button (6), the door moves once
into each end position, OPEN and CLOSED. During
this process, the control system stores the required
forces. Subsequently, LED (1 red) flashes. The
garage door operator is taught in. The values are
stored even in the event of a power failure.
7 Safety equipment
8 Preparation for installation
9 Assembly
10 Commissioning
11 Teaching in garage door operator
POWER
PROG
CANC
TEST
5
6
1
2
Содержание Gamma 60
Страница 112: ...GAMMA 60 80 Version 1 0 111 147 A3 A4 M1 50mm 3 5 10 7 10 13 17 B B B BB BB...
Страница 113: ...112 147 Version 1 0 GAMMA 60 80 M2 M3...
Страница 114: ...GAMMA 60 80 Version 1 0 113 147 M4 A A 5 7 cm 5 7 cm L1 5 N2...
Страница 115: ...114 147 Version 1 0 GAMMA 60 80 M5 1 2 3 4 O P R D 5...
Страница 116: ...GAMMA 60 80 Version 1 0 115 147 M6 M7 L4 F1 L5 L1 L2 L4 L3 F1 F F1 F2 3 F3...
Страница 117: ...116 147 Version 1 0 GAMMA 60 80 M8 M9 click 10...
Страница 148: ...Das ist die letzte Seite in diesem...