![ATS US-2000 V5 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ats/us-2000-v5/us-2000-v5_service-manual_3005199008.webp)
Mechanical settings
US
-
2000
(
DCP 2000 V
V5)
SERVICE MANUAL
CE
Fertigstellung: 02.16
US - 2000
g
g
Serviceanleitung_US2000V5_EN_V0.0.docx
Page 7 of 23
2.2.
Encoder
The encoder measures the band during the infeed and drawback
of the band.
To ensure a consistant over lap, the o-ring of the encoder should
get replaced once a year.
The tension spring on the encoder applies pressure to the
encoder wheel, so it does not jump on the band. The spring
needs to be replaced if stretched.
2.3.
Anvil
The anvil provides counter pressure for the clamp when the tape is
pulled back and also for the Sonotrode during the welding process.
The anvil moves horizontally to release the tape after welding.
2.3.1. Adjusting play of the Anvil
In order to have a good welding, the play of the
anvil should be kept at a minimum when it is in the
front position.
1.
To check the play, the anvil must be in the front position and not
clamped.
>
infeed position of the servicemode
2.
The left guide is the reference and must be pushed all the way to the
left (no gap between the aggregate and bronze guide) then
tightened.
3.
Adjust the play of the anvil with the right guide to a minimum but
make sure that it does not get pinched as the anvil moves in the
front position.
4.
Check the play again after tightening all four screws. Even with only
one spring it should pull the anvil back in the front position.
5.
Reattach both springs. Make sure that the springs are rotated one-
half turn to prevent them from getting stuck on the underside of the
rear table.
Note:
Always use the two shorter screws on the front side of the anvil.
Left bronze guide
right bronze guide
g
g
right
g
ht
(
t bronze guide
tt
g
g
to adjust the play
y
)