2.11.3 Ejection Pin Adjustment
The ejection pins push the banding out from under the
metal guides when the arch opens to draw down. The
pin should be adjusted such that during tape infeed the
tape does not hit any of the pins as the banding is fed
around the arch. Each pin has a setscrew for
adjustment
3. Machine Sensors
3.1.1 Photo Sensors
These are the eyes on the backside of the arch that
will see the product and initiate tensioning. Usually
when these are bad, the machine will not cycle at all.
Older models of the US-2000 bander have sensors on
them that can be adjusted for sensitivity. Newer
models do not have this feature. This sensor is used in
Automatic & Manual
modes. The height of the sensor
is adjustable.