MC22LV SERIES
– MASTER CLOCKS
REV 3/17/15
APPLIED TECHNICAL SYSTEMS
PAGE 4
ELECTRICAL
Power:
Standard power required is from 20 VAC to 28 VAC, 60 HZ at 8 VA
maximum. A Power Module is provided with 120 VAC input to 24 VAC
500mA output. An optional larger 1.66 Amp Power Module is available
for powering some add-on accessories. Contact the factory for details.
Outputs:
MC22LV - Two relays (SPDT) rated at 15A, 48 VAC or 24 VDC resistive.
RS232 I/O:
For connecting to a computer, or to other ATS devices such as: Digital
Clocks, GPS Systems, Ethernet Interface, and other compatible serial
data products.
Wiring:
A c
learly labeled terminal block is provided inside the MC22LV.
.
POWER FAIL BACKUP
Non-Volatile Memory keeps time and programs for indefinite power outages. All outputs and the
display are disabled during backup. The MC22LV resumes normal operation when power returns.
If the master clock has been without power for more than 48 hours a “Unit Power Fail” message
will appear when power is restored. Times and program will be intact, however pressing the [3]
key will begin the AUTO PROMPT sequence. Check time, date, day, etc. to insure accuracy, then
press the [EXIT].
ACCURACY
Time Keeping
- Synchronous with the AC power line. During a power failure, or when crystal time
base is selected, timekeeping is crystal controlled with an accuracy of +/- 4 PPM throughout its full
temperature range.
Programmed Events
- On/Off events are programmable with a one-minute resolution and occur
at the zero second of that minute.
Operating Temperature Range - 0 to 50 degrees C
PHYSICAL
MC22LV:
Black, painted aluminum enclosure - 4.8"W X 8"H X 1.8"D.
Mounting holes are provided in the enclosures for easy installation.