MC22LV SERIES
– MASTER CLOCKS
REV 3/17/15
APPLIED TECHNICAL SYSTEMS
PAGE 16
Enter 00 for the Start month and press [ENTER]. The plan will be cleared. There is no need to
clear the end date once the start date has been cleared. If you are programming the clock from a
restart, the annual and basic program steps will be cleared already.
6.5 CLEARING THE ANNUAL AND BASIC PROGRAMS
[C] [ENTER]
If you are re-programming a previously programmed clock you will need to erase any previous
programs as they could conflict with your new program. To clear all program steps, press the
CLEAR [C] key. The display will respond with:
Press [ENTER]. The display will respond with:
To clear the Annual program, press [A]. The display will return to the time display. To clear the
Basic program instead, press [B].
Choose a Basic Plan number to clear or press [A] to clear all Basic Plans.
If you wish to clear both the annual and basic programs, repeat the process a second time. Only
one can be cleared at a time.
7.0 SPECIAL FUNCTIONS
7.1 MANUAL OPERATION OF THE OUTPUT RELAYS
[1] [ENTER]
WARNING!! Manually controlling the relays will affect the loads connected to the Master
Clock. Operating these loads at the wrong time may cause damage, injury or disruption of
activities. Be aware of what is being operated by the relays and let others know that this is
about to take place.
To manually control the output relays from the keyboard, press the MANUAL [1] key. The
display will respond with:
Press [ENTER]. The display will respond with:
Command? 0C
Press ENTER
Clear buffers:
A=ANNUAL B=BASIC
Press 0-
9 or “A”
for all sets
Command? 01
Press ENTER
Manual Control
Relays: - -