9
GB
critical screw fastenings (e.g. wheel nuts) by re-tightening
with a torque wrench.
20. Use suitable hearing protection when using the appli-
ance.
21. The pre-set Newton metre settings are the nominally de-
termined manufacturer details for original tyres from the
original manufacturer. Please contact a specialist in the
event of any doubt with regards to the tightening torque
of your tires.
22. Please consult the vehicle operating instructions.
Appliance description
Display
Rotation direction
change button R/L
Diodes for the rotation
direction display
Working lamp
Main switch
+
/
–
buttons
Exchangeable fuse
Adapter for socket wrench
Technical Data
Model
10.052.9
Rated voltage
12 Volt
Rated frequency
DC
Rated input
120 Watt
Rated current
10 A
Short-term use
3 Min.
Protection rating
III
Weight
2 kg
Noise emissions
95 dB (A)
Design