Main
→
E1 SETUP
→
Idle Code
Selects the idle
code transmission
7F
– Symbol in HEX.
FF
– Symbol in HEX.
Pass
–Pass through E1
Rx timeslot data to Tx.
Pass
Main
→
E1 SETUP
→
Line Coding
Select E1 port
coding, frame
structure
AMI
HDB3
HDB3
Main
→
E1 SETUP
→
Impedance
Selection of E1
link interface
BNC
– unbalanced 75
ohms interface
RJ48C
– balanced
120 ohms interface
RJ48C
Main
→
E1 SETUP
→
Clock source
Selects System
reference clock
INTERNAL
- follow
internal oscillator
E1 (G703)
–locked to
E1 recovered receive
clock. In case the E1
receive signal is lost,
switches to the
internal oscillator
automatically.
DTE/DCE
–follow
user data port receive
clock.
E1 (G703)
Main
→
TS
Mapping
Select use timeslot
and operating data
rate
ALL
– Setting all
timeslot to carry data
or non-used.
*
- enable timeslot to
carry data
F
– inhabited by
Framing
Enable timeslot
1 for data port
Main
→
DTE/DCE
SETUP
→
DSR
Option
Main
→
DTE/DCE
SETUP
→
CTS
Option
Select data port
control signal
operate mode
Follow SYNC
–
When E1 link
synchronization,
signals will be active
ALWAYS ON
–
Enable always
Follow SYNC