11
Loopback button
When depressed, activates LL / DL / Normal
cycle.
3.3 Operating Instructions
WireSpan 600 / 610 are designed for unattended operation. After
settings are completed, WireSpan 600 / 610 operates automatically.
Connect the AC power adapter to the mains outlet, the WireSpan 600 /
610 powered on automatically. Initially, WireSpan 600 / 610 performs a
self-test. Observe the following top-panel indicator:
z
During the self-test, all the WireSpan 600 / 610
indicators should illuminate: confirm that all are
operating
z
During the test second step, all the indicators except
PWR must blinks
z
Following the test, all the indicators except PWR
WireSpan 600 / 610 are now ready for operation.
Normal Indications
During normal operation, the PWR and SYN indicators must light.
All the other indicators must be off.
Fault Indications
If a fault occurs, the BPV and/or AIS alarm indicators light, and data
transfer may be interrupted. To obtain additional information, observe the
state of the LCD screens and then refer to
Troubleshooting Instructions
for
troubleshooting information.
3.4 LCD displays
The following sections describe the major options of the menu tree.
Please refer to
Appendix B
for detail structure of the menu tree.
Not:
The section provide with WireSpan 600 unit only
3-3